Oki Data CONFIDENTIAL
4.2.15 Plate-Stay(L)
(1) Remove the scanner unit. (See to 4.2.10)
(2) Detach the Cover-Stay-L. (See to 4.2.13)
(3) Pull and unlatch the end of the printer-section side of the Arm-Link from the Shaft
of the Bracket. (See to 4.2.13)
(4) Remove the two screws (silver) ① and detach the Cover-inner-L-sub ② .
(5) Remove the six screws (silver) ③ and detach the Stay-L ④ .
①
②
③
x6
④
45850101TH Rev.1
4.2.16 Plate-Stay(R) / Plate-Board-R-Assy / Plate-
Support(Stay)
(1) Remove the scanner unit. (See to 4.2.10)
(2) Detach the Cover-Stay-R. (See to 4.2.13)
(3) Remove the Main board. (See to 4.2.8)
(4) Detach the HDD Assy and Plate Assy.-Sensor. (See to 4.2.8)
(5) Pull and unlatch the end of the printer-section side of the Arm-Link from the Shaft
of the Bracket. (See to 4.2.13)
(6) Remove the two screws (silver) ① and detach the Cover-inner-R-sub ② .
(7) Remove the Stapler Unit. (See to 4.2.9)
(8) Remove the five screws (silver) ③ and detach the Stay-R ④ .
4. REPLACEMENT OF PARTS
①
②
④
③
x5
4-35