Oki MC873dn Maintenance Manual page 52

Hide thumbs Also See for MC873dn:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
No. Category PJL Status
Panel messages
Code
126 Error
-
Use genuine
350
%COMPANY_
351
NAME%
352
consumables for
353
max performance.
+
Information
127 Error
-
Use genuine
560
%COMPANY_
561
NAME%
562
consumables for
563
max performance.
+
Information
128 Error
40580
Caution, unknown
709
Consumable
detected
Go to User Manual
"Trouble Shooting"
to restore operation
129 Error
40364
Receiving data
(ONLINE)
timeout.
519
130 Error
40486(Y)
Incompatible
690
40487(M)
%COLOR% Image
691
40488(C)
Drum.
692
40485(K)
693
Press the [Details]
button for help.
45850101TH Rev.1
Description
This should be appeared after the
drum life error messages when
OKIORIGINALCONSUMABLEDISPLAY is ON to
display this.
This should be appeared after the
drum life error messages when
OKIORIGINALCONSUMABLEDISPLAY is ON to
display this.
Unknown Consumable detected. Use a special
startup(Press Cancel when power on) to start the
printer to on-line, but a history will be recorded.
When receiving data by Port9100, LPR, FTP, IPP,
WSD, or Email, a timeout occurred in stream.
The signature ID of image drum is not proper
to the distribution channel, but the group of
signature ID is proper.
As probable missing to measure the amount of
drum, the printer notifies error status and stop
printing.
Error 690 : Y
Error 691 : M
Error 692 : C
Error 693 : K
When this error occurs in more than one color
drums, the all drums that have this error status
and a high most priolity error code are displayed.
(Example)
When this error occurs in all drums: YMCK Drum
Regional Mismatch: 690
When this error occurs in MC drums: MC Drum
Regional Mismatch: 691
No. Category PJL Status
Panel messages
Code
131 Error
40492(Y)
Incompatible
700
40493(M)
%COLOR% Image
701
40494(C)
Drum.
702
40491(K)
703
Press the [Details]
button for help.
132 Error
40496(Y)
Incompatible
704
40497(M)
%COLOR% Image
705
40498(C)
Drum.
706
40495(K)
Please see HELP
707
for details
2. TROUBLESHOOTING PROCEDURES
Description
The signature ID of image drum is not proper
to the distribution channel, and the group of
signature ID is not proper.
Error 700 : Y
Error 701 : M
Error 702 : C
Error 703 : K
When this error occurs in more than one color
drums, the all drums that have this error status
and a high most priolity error code are displayed.
(Example)
When this error occurs in all drums: YMCK Drum
Regional Mismatch: 700
When this error occurs in MC drums: MC Drum
Regional Mismatch: 701
The signature ID of image drum is not proper
to the distribution channel, and the group of
signature ID is protected.
Error 704 : Y
Error 705 : M
Error 706 : C
Error 707 : K
When this error occurs in more than one color
drums, the all drums that have this error status
and a high most priolity error code are displayed.
(Example)
When this error occurs in all drums: YMCK Drum
Regional Mismatch: 704
When this error occurs in MC drums: MC Drum
Regional Mismatch: 705
2-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es8473

Table of Contents