Oki MC873dn Maintenance Manual page 115

Hide thumbs Also See for MC873dn:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
Item1
Item2
Item3
Password
Scanner
Adjust Mech. Adjust ADF
Maintenance
Adjust CIS
45850101TH Rev.1
Item4
Item5
Value
ADF Hopping
10 ~ 1400 [mA]
Motor
Drive
300Color
Current
ADF Transfer
10 ~ 1400 [mA]
Drive
300Color
Current
ADF Hopping
10 ~ 1400 [mA]
Drive
600Color
Current
ADF Transfer
10 ~ 1400 [mA]
Drive
600Color
Current
ADF Keep
10 ~ 1400 [mA]
Current
Adjust CIS
simple
R continuous
G continuous
B continuous
All continuous
Check CIS
300dpi
600dpi
---Results Displayed---
CCD_SIG9_WID_H 0x000000
CCD_SIG2_WID_H 0x000000
Default
Default
Default
value
value
value
ODA
OEL
JP
960 [mA]
960 [mA]
1050 [mA] 1050 [mA]
1180 [mA] 1180 [mA]
1200 [mA] 1200 [mA]
200 [mA]
200 [mA]
Only for engineering test
Sequentially light the designated RGB colors and check them during
calibration configuration duties.
Move the CIS to the standard position.
In the position moved to, sequentially light R, followed by G and B in
the same manner.
Light each color for approximately 3 seconds.
Display "Testing" during execution?
→ On the panel, display "CIS light testing" and "Cancel."
Only for engineering test
Check CIS maintenance displays the exposure time at each
resolution.
When resolution is set, scanner calibration is conducted at that
resolution and the
following results are displayed:
Red-1
Red-2
Green-1
Green-2
Blue-1
Blue-2
Lsync
Note : CIS exposure time varies with resolution.
3. MAINTENANCE MENUS
Notes
3-6