4.2.9 HDD Assy / Plate Assy.-Sensor / Stapler Unit
(1) Remove the plate shield (Refer to section 4.2.8).
(2) Disconnect the cable of the HDD Assy ① from the Main board.
(3) Remove the three screws(silver) ② , and up slightly to detach the HDD Assy ① .
(4) Disconnect and remove the cord ③ , and remove a screw(silver) ④ to detach the
Plate Assy.-Sensor ⑤ .
(5) Remove the screw (silver) ⑥ and detach the Holder-WLAN ⑦ with the WLAN-
cable ⑧ .
(6) Remove the three screws (silver) ⑨ and disconnect the cables from the Main board
to detach the Stapler Unit ⑩ .
45850101TH Rev.1
⑤
③
①
②
④
⑧
⑦
②
⑥
⑨
⑩