Oki Data CONFIDENTIAL
4.2.34 Cover-FaceUP-B
(1) Open the Cover Assy.-FaceUP .
(2) To detach the Cover-FaceUP-B ① as following steps.
(a) : Turn around to about 90 degree the Cover-FaceUP-B ① as against the Cover-
FaceUP-A.
(b) : Warp the Cover-FaceUP-A to out side as the following figure.
(c) : Pull up and detach the Cover-FaceUP-B ① from the Cover-FaceUP-A.
(b)
45850101TH Rev.1
Cover Assy.-FaceUP
①
(c)
(a)
Cover-FaceUP-A
(3) Detach the Shoulder-Lock ② from the Cover-FaceUP-B ① by using the tool whose
head is flat(ex. flat-blade screwdriver), and remove two Support-Papers ③ .
②
③
Notes! The rotation direction of to detach Shoulder-Locks ② .
<Direction of to rotate for Shoulder-Locks ② >
The Shoulder-Lock ② of the left side is detached with to be rotated in a
counterclockwise direction and right side is detached with to be rotated in a clockwise
direction.
4. REPLACEMENT OF PARTS
①
4-62