Checking The Air Thermistor; Operation - APRILIA RST mille Futura 2001 Service Manual

Hide thumbs Also See for RST mille Futura 2001:
Table of Contents

Advertisement

ELECTRICAL SYSTEM
6.6.4 CHECKING
THE

OPERATION

Remove the left fairing, see 7.1.28 (REMOVING THE
SIDE FAIRINGS).
Disconnect the two-way connector (1) (green).
WARNING
When
reassembling,
connector (1) is properly connected.
Remove the thermistor (2).
As shown in the figure, connect a tester (3) (in ohm
meter mode) to the thermistor (2).
Immerse the thermistor (4) in a container (3) of water.
In the same container, immerse a thermometer (5) with
a range of 0 -150°C (32 -302°F).
Place the container on a burner (6) and slowly heat the
fluid.
Check the temperature shown on the thermometer (5)
and the thermistor value shown on the tester.
Make sure that the value changes based on temperature,
as indicated.
Water temperature
(°C)
(°F)
0
32
20
68
40
104
60
140
80
176
100
212
If the values do not change, or differ too much from
those given in the table, replace the thermistor (2).
6
- 18 -
00
AIR
THERMISTOR
make
sure
the
electrical
Standard values
(W) (± 10%)
5457
2375
1111
563,8
306,4
176,7
+
-
3