CLEARANCES
Clearance to non-combustible material
Always place a non-combustible insulation plate (false back wall), at least ½" (12 mm)
thick between the appliance and a non-combustible rear and side wall. Maintain a free
space of at least ¾" (2 cm) on either side of the insulation plate.
Minimum clearances as shown in fi gure 2 must be maintained.
(See also fi gure 13 and 14.)
Non combustible material
Insulation board
Appliance
Figure 2: Clearances to non-combustible material