INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE Gas fires with closed combustion system Bellfires wishes you many cosy evenings with your new Bellfires gas fire This document is an essential part of your gas fire. Read it carefully before installation and use of the...
Page 2
Bellfires English BELLFIRES GAS FIRES WITH CLOSED COMBUSTION SYSTEM: Derby Derby II Jersey Flat Bell Topsham Topsham Tunnel York Kent Retro Bell Large Retro Bell Intermediate Retro Bell Small Retro Bell Solo View Bell Corner Bell Large Corner Bell Small...
Page 3
Bellfires English Instructions for use and installation instructions...
Bellfires has an obligation under the terms of this warranty (at its discretion) not to charge for the replacement of any component parts. Note: The following aspects are not covered under the terms of the warranty:...
Page 7
Bellfires English Instructions for use and installation instructions...
INSTRUCTIONS FOR USE INTRODUCTION Congratulations on your purchase of this modern Bellfires gas fire. This quality product will provide you with many years of enjoyment due to the flame effect and warmth that it provides. Please read the instructions for use carefully before using the appliance for the first time.
Page 9
Bellfires English Ensure at all times that children and other people who are not aware of the operation of the gas appliance are only in the vicinity of the appliance exclusively under supervision. Use a fireguard to protect the people and children mentioned above against possible burns.
Page 10
Bellfires English 2.4.1 Igniting the fire • Open the gas supply valve in the gas pipe to the appliance. • Press in the control knob and turn it (clockwise) as far as possible. It is now in the “off” position.
Page 11
Bellfires English 2.5.2 Hand-held transmitter The remote control works by radio signal. The signal code default setting is factory set, but may be modified if requierd. Figure 2: Hand-held transmitter Set the display Connect the batteries. By simultaneously pressing OFF and , can be switched from °F (and 12 hour clock) to °C (and 24 hour clock), or vice versa.
Page 12
Bellfires English Programming the timer: P1 and P2 Select the desired mode of operation by pressing the SET button briefly. Press the SET button until P1 (heating period 1) flashes. Set the time for the beginning of the first heating period by pressing for hour and for minute’setting.
Page 13
Bellfires English Connection Piezo Igniter (only for MANual control) ON/OFF Switch Operating Knob 8 Wire Receiver Jack Motor-Knob Microswitch (in maximum position) Figure 4: Gas regulating block; Operating Knob in ON-position Possible error messages: Long beeps (0.8 secs on, 0.2 secs off) during ignition: Receiver batteries need changing soon (having heard this signal, the appliance can be ignited another ten times approximately).
Page 14
Bellfires English Switching off the appliance Press the button to lower the flames or to switch off the burner (“STAND BY”). Then press the -OFF button to switch off the appliance, including the pilot light. Press the “O I” switch (on the gas control block) to the “O” position. This conserves battery life.
Page 15
Bellfires English 2.5.4 Operation (Hand control) In an emergency it is possible to operate the appliance manually. To do so, the ignition (piezo) cable must first be removed and transferred carefully to the piezo connector on the gas control block.
Page 16
Bellfires English Move the operating knob to the ON position. Depending on the position of the motor- knob, the burner will either ignite or not. By turning the motor-knob anti-clockwise to the desired position, the burner will ignite and the flame height can be controlled.
Page 17
Bellfires English If anything is spilt on the fire, switch it off immediately and wait for it to cool down sufficiently before cleaning. Never use scouring powder, aggressive cleaners or fire polish on the gas fire. Use only a dry lint free cloth.
Bellfires English INSTALLATION INSTRUCTIONS 3.1 GENERAL The gas fire must be positioned and connected as a “room sealed system” (balance flue) appliance by a CORGI registered gas installation engineer in accordance with the following installation instructions, nationally and locally applicable regulations (see “Technical Details/ Regulations”...
Page 19
Bellfires English 3.2 BARBAS AND ONTOP CONCENTRIC FLUE Ø100 MM - Ø150 MM SYSTEM The appliance is in combination with the concentric flue system [Ø100 mm – Ø150 mm] (either rigid or flexible) of Barbas or Ontop (US system) compliant with the European CE norm for gas appliances, and may therefore only be used with these systems.
Page 20
Bellfires English 3.3.1.2. Positioning the outlet to avoid affecting the surrounding area All listed “distances” in this section are no more than guidelines. For the exact minimum “distances”, please consult your national and local directives. Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to: A.
Page 21
Bellfires English Wall-mounted outlet: To avoid adverse effects Distance: outlet - A, B or C At walls in buildings with staggered Not permitted if A, B, or C are located heights. above the outlet. On a wall - general. (*) Above the outlet: >2 m...
Page 22
Bellfires English GENERAL SERVICES 3.4.1 The Fume Channel/Combustion Air Intake The combined fume channel and combustion air intake requires one of the following Barbas or Ontop concentric flue system configurations. Important: Due to the high temperature of the outer walls (approx.
Page 23
0 - 0,6 m 0,5 - 1,0 m All appliances, except… 0 - 3,0 m 1,0 - 3,0 m ... Derby 0 - 0,6 m 1,0 - 2,0 m Derby II Jersey 0 - 3,6 m 2,0 - 3,0 m Horizon Bell Medium ...
Page 24
Bellfires English 10, 11, 12, 13 Item descriptions: see 3.4.2 Appliance: Distance Y Assemble (min.-max.) restriction plate All appliances, except… 2,0 - 11,0 m ... Jersey ... Vertical Bell Small 2,0 - 11,0 m Width: B = 30 mm ... Vertical Bell Tunnel ...
Page 25
Bellfires English 14, 15 10, 11, 12, 13 Item descriptions: see 3.4.2 Appliance: Distance X (*) Distance Y Distance Y Assemble (min.-max.) (min.-max.) (min.-max.) restriction plate All appliances 0 - 3,0 m 1,0 - 10,0 m 1,0 - 10,0 m (*) : (Y ) : X >...
Page 26
Bellfires English FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES 10, 11, 12, 13 Item descriptions: see 3.4.2 Appliance: Distance Y Assemble (min.-max.) restriction plate All appliances, except… 2,0 - 11,0 m ... Jersey ... Vertical Bell Small...
Page 27
Bellfires English > 45° 10, 11, 12, 13 Item descriptions: see 3.4.2 Appliance: Distance X (*) Distance Y (*) Distance Y Assemble (min.-max.) (min.-max.) (min.-max.) restriction plate All appliances 0 - 3,0 m 1,0 - 10,0 m 1,0 - 10,0 m (*) : (Y ) : X >...
Page 28
Bellfires English Item descriptions: see 3.4.2 Appliance: Distance Y Assemble (min.-max.) restriction plate All appliances, except… 2,0 - 11,0 m ... Jersey ... Vertical Bell Small 2,0 - 11,0 m Width: B = 30 mm ... Vertical Bell Tunnel ... Horizon Bell Medium...
Page 29
Bellfires English > 45° Item descriptions: see 3.4.2 Appliance: Distance X (*) Distance Y (*) Distance Y Assemble (min.-max.) (min.-max.) (min.-max.) restriction plate All appliances 0 - 3,0 m 1,0 - 10,0 m 1,0 - 10,0 m (*) : (Y ) : X >...
Page 30
Bellfires English SMART - BELL RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES REAR CONNECTION Wall Termination 10, 11, Position 12, 13 14, 15 10, 12, 13 Item descriptions: see 3.4.2 Appliance: Distance X Distance X Assemble (min.-max.)
Page 31
Bellfires English SMART - BELL RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES REAR CONNECTION 10, 11, 12, 13 14, 15 10, 12, 13 Item descriptions: see 3.4.2 Appliance: Distance X Distance Y Assemble (min.-max.) (min.-max.) restriction plate...
Page 32
Bellfires English SMART - BELL RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES REAR CONNECTION 14, 15 10, 11, 12, 13 14, 15 Item descriptions: see 3.4.2 Appliance: Distance X (**) Distance X (**) Distance Y (**) Assemble (min.-max.)
Page 33
Bellfires English SMART - BELL FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES REAR CONNECTION 14, 15 10, 12, 13 Item descriptions: see 3.4.2 Appliance: Distance X Distance Y Assemble (min.-max.) (min.-max.) restriction plate Smart Bell 0 - 0,5 m...
Page 34
Bellfires English SMART - BELL FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES REAR CONNECTION > 45° Item descriptions: see 3.4.2 Appliance: Distance X (**) Distance X (**) Distance Y (**) Assemble (min.-max.) (min.-max.) (min.-max.) restriction plate...
Page 35
Bellfires English SMART - BELL RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES AND “SNORKEL” REAR CONNECTION Item descriptions: see 3.4.2 Appliance: Distance X Assemble (min.-max.) restriction plate Smart Bell 0 - 0,5 m Figure 21: Horizontal wall outlet “Snorkel”...
Page 36
Bellfires English 3.4.2 Item descriptions for figures 9 t/m 21. FIG. NO. DESCRIPTION Gas fire Wall-mounted gas fire; Smart Bell Restriction plate; Jersey, Vertical Bell Small, Vertical Bell Tunnel, Horizon Bell Medium Chimney, min. Ø150 mm internal, totally gas tight Chimney or fireproof sleeving.
Page 37
“Snorkel” wall outlet set for Smart Bell If the appliance has been ordered with the BARBAS concentric flue/chimney system, a concentric Bellfires adapter will be supplied free of charge. : Color: RVS: Stainless steel self-colour, polished antr.: Anthracite colour lacquer, matt (**) : Adjustable roof flashing for a slope >...
Page 38
Bellfires English 3.4.3 Gas connection Operation (gas regulating block (and receiver)) within the appliance: The gas connection Ø12 mm (3/8”) is located on the right-hand side of the appliance. Operation (gas regulating block (and receiver)) outside the appliance (in the operating unit): The gas connection is situated where the operating unit is built in near to the appliance.
Page 39
Bellfires English Never use combustible materials during the installation. Ventilate the fireplace, by allowing vents above and below the fireplace. During installation of the gas fire, a clearance of 3 mm should be maintained on all sides of the appliance to allow for expansion of the appliance during operation.
Page 40
Bellfires English When fitting the appliance, it can be levelled with the adjustable feet. Position the gas supply pipe such that it can be easily mounted after installation. If the appliance has a operating unit, the gas pipe must lead to where the operating unit (built in), the gas regulating block (and the receiver) assembly are fitted.
Page 41
Bellfires English Important: Using the hand, screw the thermocouple connection (and thermocouple interrupter) into the back of the gas regulating unit. Carefully tighten another half of a turn using a number 9 fork spanner. See figure 25, 26 and Chapter 6.
Page 42
Bellfires English Remote control The photo below shows how the piping for a remote control gas regulating block must be fitted. Maximum Rate Pilot Gas Adjustment Adjustment Screw (with Screwdriver) Motor-Knob Operating-Knob (Tab 2,8 x 0,8 mm) Connection piezo cable...
Page 43
Bellfires English Operating-Knob (Remote control ↔ Hand control) Motor-Knob Connection Microswitch Piezo Igniter (Hand control) Piezo Igniter (Hand control) “O I” Switch 8-Wire Receiver Jack Connection Pilot Gas Figure 27: Gas regulating block Remote control Hand control Gas regulating block in operating unit...
Page 44
Bellfires English Appliance with operation in the separate operating unit (built in or otherwise): • Gas control block and piping supplied as an pre-assembly. First detach the bracket with the gas control block from the appliance. Fit the separate control unit max. 50 cm from the appliance.
Page 45
Bellfires English Connect up the convection package, if applicable. The optional mantle iron is intended for supporting the brickwork above the hearth. The mantle iron must rest on the brickwork on both sides so that upward building is possible. The brickwork therefore must not rest on the fireplace; there must be approx.
Page 46
Bellfires English 3.5.5.1 Ceramic log set + embers 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings. 2 Remove the embers (2x 100 gram) carefully from their packaging and spread them evenly over the burner mat and the grate around the burner.
Page 47
Embers must not be placed next to the pilot light burner Group C: Derby, Derby II, Horizon Bell Large, Horizon Bell Small, Horizon Bell Large Tunnel, Corner Bell Large Embers must not be placed next to the pilot light burner...
Page 48
Bellfires English Group D: Horizon Bell Extra Large Embers must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 49
Bellfires English Group E: Topsham Tunnel Position the logs as shown below. The photos show the situation from either side. • Embers must not be placed next to the pilot light burner Group F: Horizon Bell Small Tunnel • Position the logs as shown below.
Page 50
Bellfires English Group G (a): Jersey: Natural gas Embers must not be placed next to the pilot light burner Group G (b): Jersey: Propane Keep the burner orifices unblocked Embers must not be placed next to the pilot light burner...
Page 51
Bellfires English Group H (a): Vertical Bell Small: Natural gas Embers must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 52
Bellfires English Group H (b): Vertical Bell Small: Propane Keep the burner orifices unblocked Embers must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 53
Bellfires English Group I: Vertical Bell Tunnel Embers must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 54
Bellfires English Group J: Smart Bell Logs must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 55
Bellfires English Group K (a): Horizon Bell Medium: Natural gas Embers must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 56
Bellfires English Group K (b): Horizon Bell Medium: Propane Embers must not be placed next to the pilot light burner Keep the burner orifices unblocked Instructions for use and installation instructions...
Page 57
Bellfires English 3.5.5.2 Ceramic stones 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings. 2 Spread out the stones evenly on the bed of the burner. Do not block the burner openings! See separate notes for how to arrange the stones for the Jersey, Vertical Bell Small, Vertical Bell Tunnel and Horizon Bell Medium.
Page 58
Bellfires English Group B (a): Vertical Bell Small: Natural gas Stones must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 59
Bellfires English Group B (b): Vertical Bell Small: Propane Stones must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 60
Bellfires English Group C (a): Vertical Bell Tunnel: Natural gas Stones must not be placed next to the pilot light burner Group C (b): Vertical Bell Tunnel: Propane Stones must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 61
Bellfires English Group D (a): Horizon Bell Medium: Natural gas Stones must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 62
Bellfires English Group D (b): Horizon Bell Medium: Propane Stones must not be placed next to the pilot light burner Instructions for use and installation instructions...
Page 63
Bellfires English 3.5.5.3 Marble pebbles 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings. 2 Spread the pebbles over the whole burner bed (burner and grid around the burner).
Page 64
Bellfires English Important: Do not place any marble pebbles in front of the pilot light. Make sure that the pilot light can burn freely over the main burner. Keep the burner orifices unblocked Only this way a proper ignition of the main burner is ensured.
Page 65
Bellfires English The following restriction plate is supplied: Jersey Vertical Bell Small Vertical Bell Tunnel Horizon Bell Medium Restriction plate: Width: B = 30 mm 3.5.7 Checking the appliance following installation After installation, visually check the gas flame. When the fire is ignited, the flames should be short and blue/yellow in colour.
Bellfires English MAINTENANCE 4.1 ANNUAL MAINTENANCE It is essential that the appliance, the complete concentric flue system and the outlet are cleaned and inspected annually by a recognised fitter/gas specialist. The safe operation of the appliance will thus remain guaranteed.
Bellfires English FAULTS Possible reasons for the gas fire going out are: The concentric flue system is not installed according to one of the methods detailed in Paragraph 3.4 An incorrect “flue gas restriction plate” is fitted. The pilot light extinguishes if fumes are not exhausted or are insufficiently exhausted.
Available with control unit in appliance (bottom) or in separate operating unit, see page 82 (**) Control unit in separate operating unit, see page 82 (***) Control unit in appliance (bottom) 7.1 DERBY / DERBY II (**) 7.2 JERSEY (**) Instructions for use and installation instructions...
Page 70
Bellfires English 7.3 FLAT BELL (*) 7.4 TOPSHAM (*) Instructions for use and installation instructions...
Page 71
Bellfires English 7.5 TOPSHAM TUNNEL (*) 7.6 YORK (*) Instructions for use and installation instructions...
Page 72
Bellfires English 7.7 KENT (*) 7.8 RETRO BELL LARGE (***) Instructions for use and installation instructions...
Page 73
Bellfires English 7.9 RETRO BELL INTERMEDIATE (***) 7.10 RETRO BELL SMALL (***) Instructions for use and installation instructions...
Page 74
Bellfires English 7.11 RETRO BELL SOLO (***) 7.12 VIEW BELL (**) Instructions for use and installation instructions...
Page 75
Bellfires English 7.13 CORNER BELL LARGE (**) 7.14 CORNER BELL SMALL (**) Instructions for use and installation instructions...
Page 76
Bellfires English 7.15 HORIZON BELL EXTRA LARGE (**) 7.16 HORIZON BELL LARGE (**) Instructions for use and installation instructions...
Page 77
Bellfires English 7.17 HORIZON BELL LARGE TUNNEL (**) 7.18 HORIZON BELL MEDIUM (**) Instructions for use and installation instructions...
Page 78
Bellfires English 7.19 HORIZON BELL SMALL (**) 7.20 HORIZON BELL SMALL TUNNEL (**) Instructions for use and installation instructions...
Page 79
Bellfires English 7.21 VERTICAL BELL LARGE (**) 7.22 VERTICAL BELL LARGE TUNNEL (**) Instructions for use and installation instructions...
Page 80
Bellfires English 7.23 VERTICAL BELL SMALL (**) 7.24 SMART BELL (***) Instructions for use and installation instructions...
Page 81
Bellfires English OPERATING UNIT Instructions for use and installation instructions...
TECHNICAL DETAILS/REGULATIONS National installation regulations: Gas safety installation and use regulations 1984 plus all relevant safety and building regulations concerning fire installation Model : DERBY Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625...
Page 83
Bellfires English Model : DERBY II Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 11.5 kW : 9.5 kW...
Page 84
Bellfires English Model : JERSEY Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 9.5 kW : 6.8 kW...
Page 85
Bellfires English Model : YORK TOPSHAM KENT VIEW BELL TOPSHAM TUNNEL SANDUR SANDUR PANORAMA Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance...
Page 86
Bellfires English Model : FLAT BELL RETRO BELL LARGE RETRO BELL INTERMEDIATE Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 10.0 kW...
Page 87
Bellfires English Model : RETRO BELL SMALL RETRO BELL SOLO Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 8.0 kW...
Page 88
Bellfires English Model : CORNER BELL SMALL Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 8.3 kW : 8.5 kW...
Page 89
Bellfires English Model : HORIZON BELL EXTRA LARGE Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 14.0 kW : 12.0 kW...
Page 90
Bellfires English Model : HORIZON BELL LARGE HORIZON BELL LARGE TUNNEL CORNER BELL LARGE Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance...
Page 91
Bellfires English Model : HORIZON BELL MEDIUM Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Butane/Propane G30/G31 Nominal heat input (Gross calorific value) : 10.5 kW : 8.0 kW...
Page 92
Bellfires English Model : HORIZON BELL SMALL HORIZON BELL SMALL TUNNEL Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 9.5 kW...
Page 93
Bellfires English Model : VERTICAL BELL LARGE Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 10.0 kW : 9.5 kW...
Page 94
Bellfires English Model : VERTICAL BELL LARGE TUNNEL VERTICAL BELL SMALL Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 9.5 kW...
Page 95
Bellfires English Model : SMART BELL Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm Category of appliance Natural gas G20 Propane G31 Nominal heat input (Gross calorific value) : 6.5 kW : 4.5 kW...
Bellfires English REPLACEMENT PARTS LIST When requesting service or ordering replacement parts, please quote the model type and serial number. All parts listed in this manual may be ordered from a Bellfires dealer. Article no. Description 310995 Gas regulator block, BM 733 - 234484 (M9 Thermocouple connection) 301983 Nut Ø4 mm BM for pilot light pipe...
Page 97
à 100 ± 20 pieces gram gram gram Article no: 311011 311012 311003 321633 312914 311002 311008 310937 Derby 311880 Derby II 311880 Jersey 311883 Flat Bell 311883 Topsham 311879 Topsham Tunnel 311884 York 311879 Kent 311879 Retro Bell Large 311883...
Bellfires English 10. DISPOSING OF PACKAGING AND APPLIANCE The appliance comes in recyclable packaging. This can include: • Cardboard • Wood • Plastic • Paper Such materials must be disposed of responsibly, in line with local regulations. Batteries should be disposed of as chemical waste. Batteries must be disposed of responsibly, in line with local regulations.
Page 99
INTERFOCOS B.V. HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E-mail: info@interfocos.nl Internet:www.interfocos.com 01 - 010307 - 311813...