Bellfires VIEW BELL DERBY 3 CF Installation Instructions & Manual For Maintenance

Bellfires VIEW BELL DERBY 3 CF Installation Instructions & Manual For Maintenance

Gas fi res with closed combustion system
Hide thumbs Also See for VIEW BELL DERBY 3 CF:

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS &
MANUAL FOR MAINTENANCE
VIEW BELL
DERBY 3 CF/LF
Gas fi res with closed combustion system
Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re
This document is an essential part of your gas fi re.
Read it carefully before installation and maintenance of the
gas fi re and keep it in a safe place!
Serial number:
Production date:

Advertisement

Table of Contents
loading

Summary of Contents for Bellfires VIEW BELL DERBY 3 CF

  • Page 1 INSTALLATION INSTRUCTIONS & MANUAL FOR MAINTENANCE VIEW BELL DERBY 3 CF/LF Gas fi res with closed combustion system Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re This document is an essential part of your gas fi re. Read it carefully before installation and maintenance of the gas fi...
  • Page 3 Bellfi res English BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM: View Bell Derby 3 CF (Centre Fire) (VWBDY3 CF) View Bell Derby 3 LF (Line Fire) (VWBDY3 LF) Installation instructions...
  • Page 4 Bellfi res English Installation instructions...
  • Page 5: Table Of Contents

    Bellfi res English CONTENTS Page 1. INSTALLATION INSTRUCTIONS .............. 2. MAINTENANCE ..................3. FAULTS ...................... 4. DISMANTLING / ASSEMBLING OF THE GLASS ........5. DIAGRAM ELECTRICITY AND GAS ............6. DIMENSIONS .................... 7. TECHNICAL DETAILS/REGULATIONS ............ 8. REPLACEMENT PARTS LIST ..............9.
  • Page 6 Bellfi res English Installation instructions...
  • Page 7: Installation Instructions

    Bellfi res English INSTALLATION INSTRUCTIONS 1.1 GENERAL The gas fi re must be positioned and connected as a “room sealed system” (balance fl ue) appliance by a “Gas Safe Register” registered gas installation engineer in accordance with the following installation instructions, nationally and locally applicable regulations (see “Technical Details/ Regulations”...
  • Page 8 Bellfi res English The appliance can be fi tted with a convection package as an optional extra. This is a “convection jacket” (convection casing) for around and above the appliance, two fl exible aluminium pipes and two built-in convection vents. This enables hot air to be circulated into the room.
  • Page 9 Bellfi res English OPTIONS AND ACCESSORIES The following options and accessories can be supplied by your dealer: Part no Option Convection package View Bell Derby 3 336961 • 1x Convection casing 336960 • 1x Convection top plate 312829 • 1x Convection set General 336954 Mantle iron VWBDY3 ...
  • Page 10 Bellfi res English PREPARATION FOR INSTALLATION The following preparation must be carried out before the gas fi re can be installed. 1.5.1 Instructions for positioning the outlet 1.5.1.1 Positioning the outlet for correct operation: Roof-mounted outlet: >0.5 m Figure 1: Roof-mounted outlet This must be positioned at least 0.5 m from the roof edge;...
  • Page 11 Bellfi res English 1.5.1.2. Positioning the outlet to avoid affecting the surrounding area All listed “distances” in this section are no more than guidelines. For the exact minimum “distances”, please consult your national and local directives. “Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to: A.
  • Page 12 Bellfi res English Wall-mounted outlet: To avoid adverse effects Distance: outlet - A, B or C At walls in buildings with staggered Not permitted if A, B, or C are located heights. above the outlet. On a wall - general. (*) Above the outlet: >2 m Below the outlet:...
  • Page 13 Bellfi res English GENERAL SERVICES 1.6.1 The Fume Channel/Combustion Air Intake The combined fume channel and combustion air intake requires one of the following concentric fl ue system confi gurations. Important: Due to the high temperature of the outer walls (approx.
  • Page 14 Bellfi res English RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES Appliance: Concentric fl ue connection Ø100-Ø150 mm or Ø130-Ø200 mm 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y Concentric Concentric (min.-max.) connection...
  • Page 15 Bellfi res English 14, 15 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y Distance X (*) Distance Y Concentric Concentric (min.-max.) (min.-max.) (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm View Bell Width:...
  • Page 16 Bellfi res English FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES Appliance: Concentric fl ue connection Ø100-Ø150 mm or Ø130-Ø200 mm 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y Concentric Concentric (min.-max.) connection...
  • Page 17 Bellfi res English > 45° 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y (*) Distance X (*) Distance Y Concentric Concentric (min.-max.) (min.-max.) (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm View Bell Width:...
  • Page 18 Bellfi res English (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y Concentric Concentric (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm Width: Width: 2.0 - 4.0 m B = 30 mm B = 65 mm View Bell Derby 3 Width: Width:...
  • Page 19 Bellfi res English > 45° (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y (*) Distance X (*) Distance Y Concentric Concentric (min.-max.) (min.-max.) (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm View Bell Width: 1.0 - 11.0 m 0 - 3.0 m...
  • Page 20 Bellfi res English RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm Appliance: Concentric fl ue connection Ø100-Ø150 mm or Ø130-Ø200 mm Wall 10, 11, 13 Termination Position (100) Item descriptions: see 1.6.2 Assemble restriction plate:...
  • Page 21 Bellfi res English RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm Appliance: Concentric fl ue connection Ø130-Ø200 mm Wall Termination 110, 111, 113 Position Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y...
  • Page 22 Bellfi res English RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm Appliance: Concentric fl ue connection Ø130-Ø200 mm Wall Termination 110, 111, 113 Position Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y...
  • Page 23 Bellfi res English RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm Appliance: Concentric fl ue connection Ø130-Ø200 mm Wall 110, 111, Termination Position 110, 113 110, 111, 113 Item descriptions: see 1.6.2 Assemble restriction plate:...
  • Page 24 Bellfi res English RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø130 mm - Ø200 mm Appliance: Concentric fl ue connection Ø130-Ø200 mm Wall Termination 110, 111, 113 Position Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y...
  • Page 25 Ø100 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI (Gastec QA). Ø150 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI. AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm...
  • Page 26 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX Twin-wall balanced fl ue elbow 45°, 302298 incl. • and ‚ 302295 Vertical (roof) termination kit, L = 1360 mm (Vertical), incl. •, ‚ and „...
  • Page 27 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302189 Ceiling plate for transition Ø100 mm / Ø150 mm rigid - Ø100 mm (fl ex.). 302278 Stainless steel adapter piece (100) from fi re to fl exible, Ø100 mm external (rigid) x Ø107 mm internal...
  • Page 28 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302302 Concentric pipe with gauging orifi ce, L = 165 mm, incl. • and ‚ 302303 90° concentric bend with inspection panel, incl. • and ‚...
  • Page 29 Bellfi res English AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm BELLFIRES Color(*) Application ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302319 Concentric reduction of Ø130 / Ø200 mm Ø100 / Ø150 mm 302308 Twin-wall balanced fl...
  • Page 30 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302311 … : Stainless steel locking band Ø200 mm, quick-fastening 302248 † : Silicone seal Ø200 mm 302251 ˆ : Wall strap 302250 Set of ceiling fi nishing plates /...
  • Page 31 Bellfi res English AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm POUJOULAT FIG. ART. / DESCRIPTION ORDER 37100403 Twin-wall balanced fl ue pipe, L = 250 mm 37100404 Twin-wall balanced fl ue pipe, L = 450 mm 37100405 Twin-wall balanced fl...
  • Page 32 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 30° 37100411 Twin-wall balanced fl ue elbow 15° 37100401 37100654 Vertical (roof) termination kit, L = 140 mm 45150171 Roof fl ashing, suitable for a brick roof, with a roof pitch of 15°- 30°...
  • Page 33 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER 45150169 Roof fl ashing for existing chimney or fl at roof 37100610 Horizontal (wall) termination kit, L = min. 365 mm / max. 585 mm 45150076 Stainless steel locking band Ø150 mm, quick-fastening 45150072 Wall strap, Ø150 mm...
  • Page 34 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER 45150165 Roof support, (universal) Ø150 mm 45150081 Floor support, (universal) Ø150 mm 37100611 Adapter: Bellfi res Ø100-150 mm Poujoulat PGI Ø100-150 mm (Appliance 100/150 Poujoulat PGI 100/150) 37100614 Adapter: Bellfi res Ø130-200 mm Poujoulat PGI Ø100-150 mm (Appliance 130/200 Poujoulat PGI...
  • Page 35 Bellfi res English AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm POUJOULAT FIG. ART. / DESCRIPTION ORDER 37130403 Twin-wall balanced fl ue pipe, L = 250 mm Twin-wall balanced fl ue pipe, 37130404 L = 450 mm Twin-wall balanced fl...
  • Page 36 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 30° 37130411 Twin-wall balanced fl ue elbow 15° 37130401 37130610 Horizontal (wall) termination kit, L = min. 425 mm / max. 585 mm 45200076 Stainless steel locking band Ø200 mm, quick-fastening 45200072 Wall strap, Ø200 mm...
  • Page 37 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER 37130407 Concentric pipe with inspection opening, L = 250 mm 45200165 Roof support, (universal) Ø200 mm 45200081 Floor support, (universal) Ø200 mm 37130615 Adapter: Bellfi res Ø130-200 mm Poujoulat PGI Ø130-200 mm (Appliance 130/200 Poujoulat PGI 130/200)
  • Page 38 Bellfi res English AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm ONTOP FIG. ART. / DESCRIPTION ORDER USA 10 Adapter for Bellfi res appliances with Ø100-Ø150 mm concentric connection US 25 10 Twin-wall balanced fl ue pipe, L = 250 mm US 50 10 Twin-wall balanced fl...
  • Page 39 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 15° USB 15 10 USDVC2 10 Vertical (roof) termination kit, L = 375 mm, incl. • USSR 10 Storm collar Ø150 mm USLS 10 Adjustable roof fl ashing. Roof pitch 20°...
  • Page 40 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USKB 10 • : Locking band, quick-fastening USAB 10 ‚ : Cover band, screw-fastening USMB 10 Wall strap, adjustable USEB 10 Fitting bracket USCP 10 Set of ceiling fi nishing plates / Fire stops / Centring plates USDQ 10 Roof support...
  • Page 41 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USSAN2 10 Bottom renovation set USKBS 10 Locking band, screw-fastening USI 10 Concentric pipe with inspection panel, L = 250 mm USEM 10 Concentric pipe with gauging orifi ce, L = 150 mm USBI 10 90°...
  • Page 42 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USVG 10 13 Concentric reduction of Ø100-Ø150 mm Ø130-Ø200 mm AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm ONTOP FIG. ART. / DESCRIPTION ORDER USA 13 Adapter for Bellfi...
  • Page 43 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 45° USB 45 13 Twin-wall balanced fl ue elbow 30° USB 30 13 Twin-wall balanced fl ue elbow 15° USB 15 13 USDVC2 13 Vertical (roof) termination kit, L = 375 mm, incl.
  • Page 44 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USDP 13 Roof fl ashing for existing chimney or fl at roof USDPAL 13 Roof fl ashing - Aluminium for existing chimney or fl at roof USDHC4 13 Horizontal (wall) termination kit, L = 475 mm (horizontally adjustable)), incl.
  • Page 45 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USDQ 13 Roof support USSAN 13 Renovation set USSAN1 13 Top of renovation set USSAN2 13 Bottom renovation set USKBS 13 Locking band, screw-fastening USI 13 Concentric pipe with inspection panel, L = 250 mm USEM 13 Concentric pipe with gauging orifi...
  • Page 46 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USBI 13 90° concentric bend with inspection panel Rosette smooth Ø200 mm USR 13 Wall plate large Ø200 mm, 350 mm USMPG 13 Spacer bracket ASAH 13 Concentric reduction of Ø130-Ø200 mm USVG 13 10 Ø100-Ø150 mm •...
  • Page 47 Bellfi res English 1.6.3 Gas connection Operation (gas regulator block (and receiver)) outside the appliance (in the operating unit): The gas connection is situated where the operating unit is built in near to the appliance. Use only gas piping with a minimum diameter of 1/2” and a shut-off valve. 1.6.4 Operating unit If the appliance is fi...
  • Page 48 Bellfi res English Never position the appliance directly against the rear wall, but always place an nonfl ammable insulation plate, at least 12 mm thick, between the appliance and the rear wall, with free space on either side of 2 cm. (Total ± 5 cm.) The rear wall must be made of nonfl...
  • Page 49 Bellfi res English Figure 16: Appliance installed in ventilated chimney breast Horizontal outlet of the fl ue gas exhaust /combustion air supply via the wall. Fitted with the options / accessories: • convection package (= convection casing and 1x convection set) •...
  • Page 50 Bellfi res English Figure 17: Appliance installed in ventilated chimney breast Vertical outlet of the fl ue gas exhaust / combustion air supply via the roof. Fitted without convection package Inlet opening (appliance) convection air Inlet opening (grate) (chimney breast) convection air Natural convection in the chimney breast Outlet opening (grate) (chimney breast) convection air (2x) Concentric fl...
  • Page 51 Bellfi res English When fi tting the appliance, it can be levelled with the adjustable feet. These adjustable feet can be reached via the openings (4x), after removing the protective covers, in the corners of the fl oor of the combustion chamber. The fl...
  • Page 52 Bellfi res English Position the gas supply pipe such that it can be easily mounted after installation. Because the control system is outside the appliance, the gas pipe must lead to where the operating unit (built in), the gas regulator block (and the receiver) assembly are fi...
  • Page 53 Bellfi res English 1.7.1 Gas connection operating unit Important: During gas connection, take care not to twist the gas regulator block. Make sure that both the gas regulator block and the supply pipes are not subjected to stresses. The appliance is supplied with a built-in operating unit. Operating unit Frame with door (white)
  • Page 54 Bellfi res English Important : Cement and chalk can damage the piping and can, in turn, lead to gas leaks. Disassembly and assembly of pipes and cables: If necessary for mounting, all pipe compression fi ttings and cable connectors can be temporarily disassembled.
  • Page 55 Bellfi res English Pilot Gas Adjustment Screw Adjustment Screw (Pierce the housing with Maximum a small screwdriver) Burner pressure Motor-knob 8 Wire connecting Microswitch cable receiver Figure 20: Gas regulator block - Front Adjustment Screw Minimum Burner pressure Inlet Pressure Tap Outlet Pilot light Pressure Tap...
  • Page 56 Bellfi res English Thermocouple Thermocouple voltage / current voltage / current Piezo cable OUT - connection (yellow) IN - connection (red) connection Connection 8 wire cable gas regulator block Connection for AUX: external operating Electrical (option) connection for gas valve 6 VDC Adapter “rear burner”...
  • Page 57 Bellfi res English 1.7.2 Connecting the concentric fl ue Assemble the concentric fl ue system according to one of the examples in section 1.6.1, fi gure 4 to 14 inclusive. Make sure that all connections are completely gas tight. 1.7.2.1 Mounting the convection package (option) The convection package (option) consists of a convection casing and a convection set.
  • Page 58 Bellfi res English Position the two fi tting boxes in the fi replace, at a minimum distance of 30 cm under the ceiling. Mount the other end of the aluminium pipes onto the fi tting boxes. To do this use the hose clamps supplied. When the fi replace is completely fi nished, mount the grilles onto the fi...
  • Page 59 Bellfi res English Mantle iron (option). The optional mantle iron is intended for supporting the brickwork above the appliance. The mantle iron must rest on the brickwork on both sides so that upward building is possible. Level the mantle iron with the supplied bar set. Mantle iron in combination with the 10 cm frame (option).
  • Page 60 Bellfi res English Fix the mantle iron to the rear wall with the bar set. Place the draw bars at an angle of about 60˚ (between the appliance and the wall). Level the mantle iron with the tension sleeves. 2 mm Ensure that the height between the mantle Keep a clearance of 2 mm between the iron and the underside of the glass is the...
  • Page 61 Bellfi res English DO NOT COVER Do not cover the top side of the appliance with (built-in) materials. Once the fi replace has been fi nished, you can now, fi t the frame with the small door to the operating unit. After installation in a new fi...
  • Page 62 Bellfi res English 1.7.4 Checking the gas connection After connection of the gas supply, check that all connections are completely gas tight using soapy water or a leak tester. 1.7.5 Positioning the ceramic log set or marble pebbles The appliance can be supplied with: •...
  • Page 63 Bellfi res English 1.7.5.1 Ceramic log set + chips of wood + embers + vermiculite granules 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings. 2 Remove the embers carefully from their packaging and spread them evenly over the burner mat and the grate around the burner.
  • Page 64 4 Place the logs on the burner: Natural gas-burner Propane / Butane-burner Appliance see fi gure: see fi gure: View Bell Derby 3 CF/LF Keep the burner orifi ces unblocked !!! 5 Place the chips of wood around the burner. Installation instructions...
  • Page 65 Bellfi res English Logs: Log no u Log no v Log no w Log no x Log no y Log no z Log no { Log no | Installation instructions...
  • Page 66 Embers must not be placed next to the pilot light burner Keep the burner orifi ces unblocked! Figure 24: Log set View Bell Derby 3 CF/LF Position natural gas burner Embers must not be placed next to the pilot light burner Keep the burner orifi...
  • Page 67 2 Spread the pebbles over the whole burner bed (burner and grid around the burner). Make sure that the pilot light remains free. View Bell Derby 3 CF/LF : see fi gure 27 IMPORTANT: Open area, in order to ensure free accessibility of the pilot fl...
  • Page 68 Keep the burner orifi ces unblocked! Figure 27: Marble pebbles View Bell Derby 3 CF/LF Position natural gas and propane/butane burner Important: • Do not place any marble pebbles in front of the pilot light.
  • Page 69 Bellfi res English Important: Ensure that the correct fl ue gas restriction plate is mounted. Use of the correct fl ue gas restriction plate will provide optimum effi ciency, fl ame effect and combustion. Mounting an incorrect fl ue gas restriction plate can result in damage to the gas fi...
  • Page 70 Bellfi res English The following restriction plates are supplied: Concentric fl ue connection appliance [Ø130 - 200 mm] [Ø100 - 150 mm] Restriction plate: Horizontal wall outlet Roof-mounted outlet Width: B = 30 mm Width: B = 40 mm B = 40 mm Width: B = 50 mm B = 50 mm...
  • Page 71 Bellfi res English Left overpressure hatch is in the correct Right overpressure hatch is in the correct position. position. Check functioning of overpressure hatch. Check packing of overpressure hatch. If necessary, the packing can be replaced by lifting the hatch, tilting it and removing via the opening.
  • Page 72: Maintenance

    Bellfi res English MAINTENANCE 2.1 ANNUAL MAINTENANCE It is essential that the appliance, the complete concentric fl ue system (where possible) and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed.
  • Page 73: Faults

    Bellfi res English FAULTS POSSIBLE REASONS Possible reasons for the gas fi re going out are: • The concentric fl ue system is not installed according to one of the methods detailed in Paragraph 1.6. • An incorrect “fl ue gas restriction plate” is fi tted. •...
  • Page 74: Dismantling / Assembling Of The Glass

    Bellfi res English DISMANTLING / ASSEMBLING OF THE GLASS 4.1 VIEW BELL DERBY 3 HIDDEN DOOR (10 cm frame (4 sided)) Dismantling of the glass: Place paperboard on the chimney breast, under the appliance. This helps prevent damage. • View Bell Derby 3 •...
  • Page 75 Bellfi res English • Remove the side panel on the right. • Remove the bottom panel, by pulling it gently to tilt forward and to remove. Prevent damage to the side glasses ! Installation instructions...
  • Page 76 Bellfi res English • Unscrew the strip at the front under the • Using a screwdriver, slide the strip a glass. Screws only need a couple of little to the left. turns! • Remove the strip at the front. • Unscrew the long strip at the top a little and leave the strip in place.
  • Page 77 Bellfi res English • Lift the glass carefully and pull it • Remove the glass by slanting it forward forwards a little at the bottom. a little at the bottom and taking it out. • The glasses at the sides can be removed in the same way as the front glass. Installation instructions...
  • Page 78 Bellfi res English Compression spring position Side glass L/R Side glass compression spring L/R • Make sure that the compression • Side glass compression spring spring (Left and Right) stays in the (Left and Right). correct position. All fastening strips on the top side remain in position! Assembling of the glasses: The assembly of the glass takes place in reverse order.
  • Page 79: Diagram Electricity And Gas

    Bellfi res English DIAGRAM ELECTRICITY AND GAS Double burner: : Perforation pattern “Centre Fire” double burner. : Perforation pattern “Line Fire” double burner. Gas pipe “Rear burner” “Rear burner” Gas pipe “Front burner” 8 Wire “Front burner” Motor- connecting knob cable Pilot light Thermocouple...
  • Page 80: Dimensions

    Bellfi res English DIMENSIONS VIEW BELL DERBY 3 - Hidden Door Fitted with the option: Convection casing Installation instructions...
  • Page 81 Bellfi res English VIEW BELL DERBY 3 - Hidden Door + 10 cm Frame Installation instructions...
  • Page 82 Bellfi res English OPERATING UNIT Installation instructions...
  • Page 83: Technical Details/Regulations

    • Gas safety installation and use regulations 1998 plus all relevant safety and building regulations concerning fi re installation • Document J: Combustion appliances and fuel storage systems Model : VIEW BELL DERBY 3 CF (Centre Fire) : NATURAL GAS : BUTANE / PROPANE Country : GB;...
  • Page 84 Bellfi res English Model : VIEW BELL DERBY 3 CF (Centre Fire) : NATURAL GAS : BUTANE / PROPANE Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Batteries remote control - Receiver : 4x 1.5V AA : 4x 1.5V AA...
  • Page 85 Bellfi res English Model : VIEW BELL DERBY 3 LF (Line Fire) : NATURAL GAS : BUTANE / PROPANE Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identifi cation no : 0063CM3684 : 0063CM3684 Type of appliance under CE-norm Category of appliance natural gas G20 butane/propane G30/G31...
  • Page 86 Bellfi res English Model : VIEW BELL DERBY 3 LF (Line Fire) : NATURAL GAS : BUTANE / PROPANE Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Batteries remote control - Receiver : 4x 1.5V AA : 4x 1.5V AA - Hand-transmitter : 1x 9V block : 1x 9V block...
  • Page 87: Replacement Parts List

    Bellfi res English REPLACEMENT PARTS LIST When requesting service or ordering replacement parts, please quote the model type and serial number. All parts listed in this manual may be ordered from a Bellfi res dealer. Article no Description 335118 Main burner “Centre Fire” 561 x 130 mm Natural gas G20 / Butane/Propane G30/G31 G20: 1x Ø10.0 mm front + 1x Ø10.0 mm rear...
  • Page 88 Bellfi res English Article no Description 321926 Thermocouple M10 - 1500 mm 333604 Thermocouple interrupter M10 310908 Pilot light set outer casing, Double fl ame 310909 Packing pilot light set outer casing 310910 Pilot light injector; Natural gas; no 36 310912 Pilot light injector;...
  • Page 89 Appliance Log set Marble pebbles Marble pebbles set (white) set (grey) Embers with Vermiculite no 4 Log no Chips of Glow-effect black wood set Anthracite fi ltered 3 pieces Bag: 125 gr. Bag: 50 gr. Bag: 2.5 kg. Bag: 2.5 kg. Art.
  • Page 90: Disposal Of Packaging And Appliance

    Bellfi res English DISPOSING OF PACKAGING AND APPLIANCE The appliance comes in recyclable packaging. This can include: • Cardboard • Wood • Plastic • Paper Such materials must be disposed of responsibly, in line with local regulations. Batteries should be disposed of as chemical waste. Batteries must be disposed of responsibly, in line with local regulations.
  • Page 92 Your Bellfi res dealer 01 - 100714 - 336997...

This manual is also suitable for:

View bell derby 3 lfVwbdy3 cfVwbdy3 lf