Gas fires with closed combustion system original bell-series - retro bell-series horizon bell medium / small-series - corner bell small l/r vertical bell-series - view bell-series (90 pages)
Page 1
INSTALLATION INSTRUCTIONS & MANUAL FOR MAINTENANCE CORNER BELL MEDIUM 3 CF/LF Gas fi res with closed combustion system Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re This document is an essential part of your gas fi re.
Page 2
Bellfi res English RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES Appliance: Concentric fl ue connection Ø100-Ø150 mm or Ø130-Ø200 mm 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y Concentric Concentric (min.-max.) connection...
Page 3
Bellfi res English 14, 15 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y Distance X (*) Distance Y Concentric Concentric (min.-max.) (min.-max.) (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm Corner Bell Width:...
Page 4
Bellfi res English FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES Appliance: Concentric fl ue connection Ø100-Ø150 mm or Ø130-Ø200 mm 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y Concentric Concentric (min.-max.) connection...
Page 5
Bellfi res English > 45° 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y (*) Distance X (*) Distance Y Concentric Concentric (min.-max.) (min.-max.) (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm Corner Bell Width:...
Page 6
Bellfi res English (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y Concentric Concentric (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm Width: Width: 2.0 - 4.0 m B = 30 mm B = 65 mm Corner Bell Medium 3 L/R Width: Width:...
Page 7
Bellfi res English > 45° (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y (*) Distance X (*) Distance Y Concentric Concentric (min.-max.) (min.-max.) (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm Corner Bell Width: 1.0 - 11.0 m 0 - 3.0 m...
Page 8
Bellfi res English RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm Appliance: Concentric fl ue connection Ø100-Ø150 mm or Ø130-Ø200 mm Wall 10, 11, 13 Termination Position (100) Item descriptions: see 1.6.2 Assemble restriction plate:...
Page 9
Bellfi res English RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm Appliance: Concentric fl ue connection Ø130-Ø200 mm Wall Termination 110, 111, 113 Position Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y...
Page 10
Bellfi res English RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm Appliance: Concentric fl ue connection Ø130-Ø200 mm Wall Termination 110, 111, 113 Position Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y...
Page 11
Bellfi res English RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm Appliance: Concentric fl ue connection Ø130-Ø200 mm Wall 110, 111, Termination Position 110, 113 110, 111, 113 Item descriptions: see 1.6.2 Assemble restriction plate:...
Page 12
Bellfi res English RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø130 mm - Ø200 mm Appliance: Concentric fl ue connection Ø130-Ø200 mm Wall Termination 110, 111, 113 Position Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y...
Bellfi res English 1.6.3 Gas connection Operation (gas regulator block (and receiver)) outside the appliance (in the operating unit): The gas connection is situated where the operating unit is built in near to the appliance. Use only gas piping with a minimum diameter of 1/2” and a shut-off valve. 1.6.4 Operating unit If the appliance is fi...
Page 14
Bellfi res English Never position the appliance directly against the rear wall, but always place an nonfl ammable insulation plate, at least 12 mm thick, between the appliance and the rear wall, with free space on either side of 2 cm. (Total ± 5 cm.) The rear wall must be made of nonfl...
Page 15
Bellfi res English Figure 16: Appliance installed in ventilated chimney breast Horizontal outlet of the fl ue gas exhaust /combustion air supply via the wall. Fitted with the options / accessories: • convection package (= convection casing and 1x convection set) •...
Page 16
Bellfi res English Figure 17: Appliance installed in ventilated chimney breast Vertical outlet of the fl ue gas exhaust / combustion air supply via the roof. Fitted without convection package Inlet opening (appliance) convection air Inlet opening (grate) (chimney breast) convection air Natural convection in the chimney breast Outlet opening (grate) (chimney breast) convection air (2x) Concentric fl...
Page 17
Bellfi res English When fi tting the appliance, it can be levelled with the adjustable feet. These adjustable feet can be reached via the openings (4x), after removing the protective covers, in the corners of the fl oor of the combustion chamber. The fl...
Page 18
Bellfi res English Position the gas supply pipe such that it can be easily mounted after installation. Because the control system is outside the appliance, the gas pipe must lead to where the operating unit (built in), the gas regulator block (and the receiver) assembly are fi...
Page 19
Bellfi res English 1.7.1 Gas connection operating unit Important: During gas connection, take care not to twist the gas regulator block. Make sure that both the gas regulator block and the supply pipes are not subjected to stresses. The appliance is supplied with a built-in operating unit. Operating unit Frame with door (white)
Page 20
Bellfi res English Important : Cement and chalk can damage the piping and can, in turn, lead to gas leaks. Disassembly and assembly of pipes and cables: If necessary for mounting, all pipe compression fi ttings and cable connectors can be temporarily disassembled.
Page 21
Bellfi res English Pilot Gas Adjustment Screw Adjustment Screw (Pierce the housing with Maximum a small screwdriver) Burner pressure Motor-knob 8 Wire connecting Microswitch cable receiver Figure 20: Gas regulator block - Front Adjustment Screw Minimum Burner pressure Inlet Pressure Tap Outlet Pilot light Pressure Tap...
Page 22
Bellfi res English Thermocouple Thermocouple voltage / current voltage / current Piezo cable OUT - connection (yellow) IN - connection (red) connection Connection 8 wire cable gas regulator block Connection for AUX: external operating Electrical (option) connection for gas valve 6 VDC Adapter “rear burner”...
Page 23
Bellfi res English 1.7.5.1 Ceramic log set + chips of wood + embers + vermiculite granules 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings. 2 Remove the embers carefully from their packaging and spread them evenly over the burner mat and the grate around the burner.
Page 24
Bellfi res English Note ! Small embers and their residue should not be scattered on • the burner. This can cause a blockage on the burner orifi ces. • Embers and vermiculite granules must not be placed next to the pilot light burner. •...
Page 25
Bellfi res English Logs: Log no Log no Log no Log no Log no Log no Log no Log no Installation instructions...
Page 26
Bellfi res English Embers must not be placed next to the pilot light burner Keep the burner orifi ces unblocked! Figure 24: Log set Corner Bell Medium 3 L/R CF/LF Position natural gas burner Embers must not be placed next to the pilot light burner Keep the burner orifi...
Page 27
Bellfi res English 1.7.5.2 Marble pebbles 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings. 2 Spread the pebbles over the whole burner bed (burner and grid around the burner). Make sure that the pilot light remains free.
Page 28
Bellfi res English Marble pebbles must not be placed Keep the burner next to the pilot light burner orifi ces unblocked! Keep the burner orifi ces unblocked! Figure 27: Marble pebbles Corner Bell Medium 3 L/R CF/LF Position natural gas and propane/butane burner Important: •...
Page 29
Bellfi res English Important: Ensure that the correct fl ue gas restriction plate is mounted. Use of the correct fl ue gas restriction plate will provide optimum effi ciency, fl ame effect and combustion. Mounting an incorrect fl ue gas restriction plate can result in damage to the gas fi...
Page 30
Bellfi res English The following restriction plates are supplied: Concentric fl ue connection appliance [Ø130 - 200 mm] [Ø100 - 150 mm] Restriction plate: Horizontal wall outlet Roof-mounted outlet Width: B = 30 mm Width: B = 40 mm B = 40 mm Width: B = 50 mm B = 50 mm...
Page 31
Bellfi res English Left overpressure hatch is in the correct Right overpressure hatch is in the correct position. position. Check functioning of overpressure hatch. Check packing of overpressure hatch. If necessary, the packing can be replaced by lifting the hatch, tilting it and removing via the opening.
Bellfi res English MAINTENANCE 2.1 ANNUAL MAINTENANCE It is essential that the appliance, the complete concentric fl ue system (where possible) and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed.
Bellfi res English FAULTS POSSIBLE REASONS Possible reasons for the gas fi re going out are: • The concentric fl ue system is not installed according to one of the methods detailed in Paragraph 1.6. • An incorrect “fl ue gas restriction plate” is fi tted. •...
Page 34
Bellfi res English DISMANTLING / ASSEMBLING OF THE GLASS 4.1 CORNER BELL MEDIUM 3 L/R HIDDEN DOOR (10 cm frame (4 sided)) Dismantling of the glass: Place paperboard on the chimney breast, under the appliance. This helps prevent damage. • Corner Bell Medium 3 - Right. •...
Page 35
Bellfi res English • Remove the side panel on the short side. • Remove the bottom panel . • Remove the bottom panel. • Unscrew the strip at the front under the • Using a screwdriver, slide the strip a glass.
Page 36
Bellfi res English • Remove the strip at the front. • Unscrew the long strip at the top a little and leave the strip in place. • Pull the glass carefully forwards at the bottom, and slide it a little to one side. Installation instructions...
Page 37
Bellfi res English • Lift the glass carefully and pull it • Remove the glass by slanting it forward forwards a little at the bottom. a little at the bottom and taking it out. • The glass at the sides can be removed in the same way as the front glass. Installation instructions...
Page 38
Bellfi res English Compression spring position Side glass compression spring • Make sure that the compression spring • Side glass compression spring. stays in the correct position. All fastening strips on the top side remain in position! Assembling of the glass: The assembly of the glass takes place in reverse order.
Bellfi res English DIAGRAM ELECTRICITY AND GAS Double burner: : Perforation pattern “Centre Fire” double burner. : Perforation pattern “Line Fire” double burner. Gas pipe “Rear burner” “Rear burner” Gas pipe “Front burner” 8 Wire “Front burner” Motor- connecting knob cable Pilot light Thermocouple...
Page 40
Bellfi res English DIMENSIONS CORNER BELL MEDIUM 3 L 6.1.1 CORNER BELL MEDIUM 3 L - Hidden Door Fitted with the options: Convection casing Installation instructions...
Page 41
Bellfi res English 6.1.2 CORNER BELL MEDIUM 3 L - Hidden Door + 10 cm Frame Installation instructions...
Page 42
Bellfi res English CORNER BELL MEDIUM 3 R 6.2.1 CORNER BELL MEDIUM 3 R - Hidden Door Fitted with the options: Convection casing Installation instructions...
Page 43
Bellfi res English 6.2.2 CORNER BELL MEDIUM 3 R - Hidden Door + 10 cm Frame Installation instructions...
Bellfi res English TECHNICAL DETAILS/REGULATIONS National installation regulations: • Gas safety installation and use regulations 1998 plus all relevant safety and building regulations concerning fi re installation • Document J: Combustion appliances and fuel storage systems Model : CORNER BELL MEDIUM 3 L/R CF (Centre Fire) : NATURAL GAS : BUTANE / PROPANE Country...
Page 46
Bellfi res English Model : CORNER BELL Medium 3 L/R CF (Centre Fire) : NATURAL GAS : BUTANE / PROPANE Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Batteries remote control - Receiver : 4x 1.5V AA : 4x 1.5V AA - Hand-transmitter : 1x 9V block...
Page 47
Bellfi res English Model : CORNER BELL MEDIUM 3 L/R LF (Line Fire) : NATURAL GAS : BUTANE / PROPANE : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Country Product identifi cation no : 0063CM3684 : 0063CM3684 Type of appliance under CE-norm Category of appliance natural gas G20 butane/propane G30/G31...
Page 48
Bellfi res English Model : CORNER BELL Medium 3 L/R LF (Line Fire) : NATURAL GAS : BUTANE / PROPANE Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Batteries remote control - Receiver : 4x 1.5V AA : 4x 1.5V AA - Hand-transmitter : 1x 9V block...
Bellfi res English REPLACEMENT PARTS LIST When requesting service or ordering replacement parts, please quote the model type and serial number. All parts listed in this manual may be ordered from a Bellfi res dealer. Article no Description 334987 Main burner “Centre Fire” 827 x 130 mm Natural gas G20 / Butane/Propane G30/G31 G20: 1x Ø12.0 mm front + 1x Ø12.0 mm rear...
Page 50
Bellfi res English Article no Description 321926 Thermocouple M10 - 1500 mm 333604 Thermocouple interrupter M10 310908 Pilot light set outer casing, Double fl ame 310909 Packing pilot light set outer casing 310910 Pilot light injector; Natural gas; no 36 310912 Pilot light injector;...