IMPORTANT SAFETY INSTRUCTIONS
20. Keep control compartments, burners and circulating air passages clean. More
frequent cleaning may be needed due to excessive lint and dust. Turn off the
gas valve and appliance (OFF on remote control) before cleaning the appliance.
21. The venting system MUST checked annually by a qualifi ed service person.
If needed, have the venting system cleaned or repaired.
22. When the appliance is installed directly on carpeting, tile or other combustible
material, it must be set on a metal panel or hearth pad extending at least the full
width and depth of the appliance.
23. DO NOT obstruct the fl ow of combustion and ventilation air in any way. Provide
adequate clearances around air openings into the combustion chamber along
with adequate accessibility clearance for servicing and proper operation.
24. DO NOT use the appliance if any part has been exposed to or has been under
water. Immediately call a qualifi ed service technician to inspect the appliance and
replace any part of the control system and any gas control which has been
submerged in water.
25. DO NOT operate the appliance if any log is broken.
26. The installation must conform with local codes or, in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and
Propane Installation Code, CSA B149.1.
27. This appliance, when installed, must be electrically grounded in accordance with
local codes or in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
28. The appliance is equipped with a safety system, whereby hatches will extract
any over-pressure in a controlled way. In this, the hatches will briefl y open.
To avoid any possible personal harm when the hatches open due to an
over-pressure, always maintain a minimum distance of 40 in (100 cm) to the
appliance, when igniting and when burning. If an over-pressure situation occurs,
the appliance should be thorougly checked by the installer.
Take care that no pipes get damaged and no compression fi ttings come
loose when moving the gas regulator block. Prevent twisting the fl exible
pipes! Check all compression fi ttings for leaks afterwards!
WARNING:
This gas is commonly known as well-headed gas.
Bellfi res
IMPORTANT:
Never connect unit to private (non-utility) gas wells.