Overheat Cut-Off Device - Baxi Solo 3 PFL 30 Installation & Servicing Instructions Manual

Wall mounted powered flue gas fired central heating units
Table of Contents

Advertisement

1
2
3
Overheat Neon
Fig. 96
Warning
© Baxi Heating UK Ltd 2009
Fig. 95
*

8.0 Overheat Cut-off Device

8.1
Operation
1. The overheat cut-off device is of the manual reset
type and therefore it is important that the user knows
how to reset the control should it ever cut out.
NOTE: Cut-out is indicated by illumination of the
neon light on the control box.
2. Remove the lower door panel by following the
sequence of diagrams (Fig 95).
3. To reset the boiler - Turn the boiler thermostat
control knob fully anti-clockwise to the OFF position
marked '0' (Fig. 96). Wait ten seconds, turn the control
knob clockwise to the required thermostat setting, the
red neon goes out, the boiler will start automatically.
4. No adjustment to the gas controls or main
thermostat are required.
5. If the overheat thermostat drops out repeatedly,
refer to the fault finding chart at the rear of this
booklet or consult a competent service engineer.
35