Introduction - Baxi Solo 3 PFL 30 Installation & Servicing Instructions Manual

Wall mounted powered flue gas fired central heating units
Table of Contents

Advertisement

1.3
Important Information
Man-Made Mineral Fibre
a) Some component parts of this appliance (insulation pads, gaskets and rope
seals) are manufactured from man-made mineral fibre.
b) Prolonged or excessive exposure to this material may result in some irritation
to the eyes, skin or respiratory tract.
c) It is advisable to wear gloves when handling these items.
d) Irritant dust will only be released from the items if they are broken up or
subjected to severe abrasion. In these instances a suitable dust mask and goggles
should be worn.
e) Always thoroughly wash hands after installation, servicing or changing
components.
f) When disposing of any items manufactured from man-made mineral fibre care
must be exercised.
g) If any irritation of the eyes or severe irritation of the skin is experienced seek
medical attention.
4
© Baxi Heating UK Ltd 2009

1.0 Introduction

1.1
Description
1. The Baxi Solo 3 PFL is a gas fired room sealed fan
assisted central heating boiler with outputs as shown in
the table below
Model
Heat Output
30
8.79kW (30,000 Btu/h)
40
11.72kW (40,000 Btu/h)
50
14.65kW (50,000 Btu/h)
60
17.58kW (60,000 Btu/h)
70
20.5kW (70,000 Btu/h)
80
23.44kW (80,000 Btu/h)
2. Each appliance is preset at a heat input rating and is
designed for use on NATURAL GAS only.
3. All boilers are suitable for fully pumped open vented
central heating and domestic hot water systems and
sealed systems.
4. The appliance data badge is fitted to the combustion
box door.
1.2
Installation
The appliance is suitable only for installation in GB and
IE and should be installed in accordance with the rules in
force.
In GB, the installation must be carried out by a Gas
Safe Registered Installer. It must be carried out in
accordance with the relevant requirements of the:
• Gas Safety (Installation & Use) Regulations.
• The appropriate Building Regulations either The
Building Regulations, The Building Regulations
(Scotland), Building Regulations (Northern Ireland).
• The Water Fittings Regulations or Water Byelaws in
Scotland.
• The Current I.E.E. Wiring Regulations.
Where no specific instructions are given, reference
should be made to the relevant British Standard Code
of Practice.
In IE, the installation must be carried out by a
competent Person and installed in accordance with the
current edition of I.S. 813 'Domestic Gas Installations',
the current Building Regulations and reference should
be made to the current ETCI rules for electrical
installation.
Read the instructions before installing or using this
appliance.
All systems must be thoroughly flushed and treated
with inhibitor (see Section 3.1).
IMPORTANT: State of adjustment - Check that the
state of adjustment given on the data plate is
compatible with local supply conditions.
1