Technical Data - Baxi Solo 3 PFL 30 Installation & Servicing Instructions Manual

Wall mounted powered flue gas fired central heating units
Table of Contents

Advertisement

Model
P Heat Output
Q Heat Input
Burner Pressure
Gas Rate
(after 10 mins)
Lifting Weight
Water Content
Outercase
Dimensions
Flue Terminal
Dimensions
Static Head
Connections
Heat Exchanger
Low Head
System Design
Gas Connection
Electrical Supply
Controls
Internal Fuse
1
© Baxi Heating UK Ltd 2009
30
kW
8.79
Btu/h
30,000
kW
10.99
Btu/h
37,500
mbar
16.0 ±0.5
in wg
6.4 ±0.2
CV 38mj/m
3
1.04m
3
/h
36.86ft
3
/h
kg
23.1
lbs
51
litres
1.1
pints
1.9
Height
600mm
Width
350mm
Depth
287mm
Diameter
100mm
Depth
70mm
Max
30 metres (100 ft)
Min
1 metre (3.25 ft)
Flow
22mm Cu tail
Return
22mm Cu elbow
Cast iron monobloc
Min
0.2m (8 in)
fully pumped open vented and sealed systems
RC
1
/
(
1
/
in BSPT)
2
2
230V ~ 50Hz fused 5A - 90W
boiler thermostat, intermittent pilot & electronic flame sensing
timed pump over-run, frost protection thermostat
4AF 250V to BS4256 situated on control board

2.0 Technical Data

40
50
11.72
14.65
40,000
50,000
14.65
18.32
50,000
62,500
16.0 ±0.5
16.0 ±0.5
6.4 ±0.2
6.4 ±0.2
1.39m
3
/h
1.74m
3
/h
49.0ft
3
/h
61.3ft
3
/h
23.1
23.1
51
51
1.1
1.1
1.9
1.9
600mm
600mm
350mm
350mm
287mm
287mm
60
70
17.58
20.5
60,000
70,000
21.98
25.64
75,000
87,500
16.0 ±0.5
16.0 ±0.5
6.4 ±0.2
6.4 ±0.2
2.08m
3
/h
2.43m
3
/h
73.5ft
3
/h
86.75ft
3
/h
32.2
32.2
71
71
1.6
1.6
2.8
2.8
600mm
600mm
462mm
462mm
287mm
287mm
80
23.44
80,000
29.31
100,000
16.0 ±0.5
6.4 ±0.2
2.78m
3
/h
99.24ft
3
/h
32.2
71
1.6
2.8
600mm
462mm
287mm
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents