Baxi Solo 3 PFL 30 Installation & Servicing Instructions Manual page 26

Wall mounted powered flue gas fired central heating units
Table of Contents

Advertisement

Fig. 69
26
© Baxi Heating UK Ltd 2009
Wall Thickness
Fig. 70
Wall Thickness - 10
Fig. 71
5.0 Installation
5.15
Internal Fitting Kit
1. A internal fitting kit (available from merchants, quote
Baxi Part N
o
. 236441BAX) is suitable for walls between
3
100mm (4in) and 285mm (11
/
16
2. TO INSTALL THE KIT - Mark the flue hole centre
as described in section 5.4 or 5.8. Cut a hole in the
masonry approximately 117mm (4
the internal fitting kit. The use of a core drill is
recommended. (When using a core drill, it is important
to keep the drill level and square).
3. Measure the wall thickness and from this dimension
subtract 10mm (
3
/
in) (Fig. 69).
8
4. Remove the wall liner from its packing and remove
the end piece (Fig. 70).
5. Mark off the dimension, wall thickness - 10mm
3
(
/
in), measuring from the beaded end of the duct and
8
cut off the remaining length of the duct. Ensure that the
cut is square and reasonably straight (Fig. 71).
in) in thickness.
5
/
in) diameter for
8