5.0 Installation

5.1
Initial Preparation
1. Unpack contents of carton.
2. Remove the lower door panel from the outer case.
Remove the 2 screws holding the outer case to the
combustion box.
3. Place the ready assembled outer case in a safe place
until required.
4. Release the R clip from the top latch securing the
combustion box to the back plate and release both
latches (Fig. 15).
5. Lift and remove the combustion box from the back
plate (Fig. 16). Place the combustion box on its back.
IMPORTANT - When installing a Solo 3 PFL with
a rear flue see section 5.2 before continuing the
installation.
6. Proceed to the relevant section for flueing the
appliance either to the Rear, Left, Right or Vertically.
NOTE: For Vertical flueing or flue lengths greater
than standard, the relevant optional extra kits must
be obtained and their instructions followed.