5.0 Installation
Wall
Thickness
5.9
Side Flue Preparation
1. For both Left and Right Hand Flue - Measure the
distance from the wall to the nearest line marked from
the template. This will be known as dimension X
(Fig. 45).
2. Measure the thickness of the wall from the inside. This
will be known as Wall Thickness (Fig 46).
3. To make up the total flue length, add 90mm
models) or 145mm (60, 70, 80 models) to the
Wall Thickness + X dimension (Fig. 47):
Total flue length =
Wall Thickness + X +
Wall Thickness + X +
NOTE: if total calculated flue length exceeds 500mm
(19
5
/
in), a flue extension kit will be required.
8
Fig. 47
CUTTING THE FLUE
NOTE: If Wall Thickness + X is less than;
195mm (30, 40, 50 models) or
140mm (60, 70, 80 models),
it will be necessary to cut the components of the flue
to make up the appropriate size.
4. Take the Flue Duct and measure the dimension below
from the flared end. Cut the waste off the plain end (Fig.
48).
Wall Thickness + X + 90mm (30, 40, 50 models)
Wall Thickness + X + 145mm (60, 70, 80 models)
5. Take the Flue Terminal Assembly and measure from
the terminal end the dimension below (Fig. 49). Cut the
waste off the plain end.
Fig. 49
Wall Thickness + X + 50mm (30, 40, 50 models)
Wall Thickness + X + 105mm (60, 70, 80 models)
6. Measure the same amount from the flange end of the
Air Duct and cut the waste off the plain end (Fig. 50).
Wall Thickness +X + 50mm (30, 40, 50 models)
Wall Thickness + X + 105mm (60, 70, 80) models
7. The cardboard support supplied in the flue pack should
be installed onto the flue tubes to ensure the assembly is
Fig. 50
supported during cutting (Fig. 51 & 52).
Cut Line
Fig. 52
(30, 40, 50
90mm (30, 40, 50)
145mm (60, 70, 80).