Baxi Solo 3 PFL 30 Installation & Servicing Instructions Manual page 18

Wall mounted powered flue gas fired central heating units
Table of Contents

Advertisement

Blanking
Cap
Air Box Blanking
Plate
Fig. 30
Flue Duct
Air Duct
18
© Baxi Heating UK Ltd 2009
Backplate
Fig. 31
Fig. 32
Tape
Fig. 33
5.0 Installation
5.6
Assembly of Rear Flue
1. Remove the rear air box blanking plate from the back
plate by releasing the three screws (Fig. 30).
2. Remove the blanking cap at the rear of the turret, by
pushing and turning anti-clockwise to release the
bayonet fitting (Fig. 30).
3. Locate the flared end of the flue duct over the
bayonet fitting on the turret, taking care not to damage
the 'O' ring. Lock the flue duct in place by pressing in
and turning clockwise (Fig. 31).
4. Engage the bayonet slots of the air duct over the
location lugs on the back plate opening and press and
turn clockwise to secure the air duct to the back plate
(Fig. 32).
5. In order to increase security of the flue, the bayonet
tags may be deformed to secure the flue in position.
6. Take the flue terminal assembly and engage on the
flue and air ducts. Slide the flues together to the desired
wall thickness.
7. Tape the sections of the outer ducts together with
the tape provided ensuring a good seal is made
(Fig. 33).