Hydraulic Resistance Charts
(52) 130
(48) 120
(44) 110
(40) 100
(36) 90
(32) 80
(28) 70
(24) 60
(20) 50
(16) 40
(12) 30
(8) 20
(4) 10
Templates
107 Dia
without
internal
fitting
Layout of Fixing Points
30, 40 and 50 models
Top of Outercase
121mm
61.3mm
6
© Baxi Heating UK Ltd 2009
2 4 6 8 1012 1416 18 2022
242628 30
Water Flow Rate litres / min
30, 40 and 50 models
25
268
75
121
117 Dia
with
internal
392
fitting
439
442
Centre of
Gas Connection
8 Slots
4
20 x 6
144
144
All Models
• This appliance is only intended for installation on a governed supply.
• PMS = 3 bar pressure class 2
• Max CH water pressure 3 bar
• Type C
C
C
12,
32,
52
• Nox class 1
• Appliance category I
• Ref: 86/AU/588
• Burner Injector Sizes: 30=B12 40=B13 50=B14 60=B15 70=B30 80=B16
• This boiler is designed to operate at a maximum water temperature of 85° C.
2H - G20 - 20mbar
2H
2.0 Technical Data
(52) 130
(48) 120
(44) 110
(40) 100
(36) 90
(32) 80
(28) 70
(24) 60
(20) 50
(16) 40
(12) 30
(8) 20
(4) 10
2 4 6 8 1012 1416 18 2022
Water Flow Rate litres / min
60, 70 and 80 models
25
380
107 Dia
117 Dia
without
with
internal
internal
392
fitting
fitting
Centre of
Gas Connection
52
196
196
Layout of Fixing Points
60, 70 and 80 models
SEDBUK Declaration For Solo 3 PFL
Model
Seasonal Efficiency
(SEDBUK) (%)
30
79.4
40
78.4
50
78.0
60
78.5
70
78.2
80
79.0
This value is used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been
certified by 0086.