Fig. 19
Combustion Box Door
Fig. 20
Fan Assembly
© Baxi Heating UK Ltd 2009
Fig. 18
Fan Assembly
Fig. 17
Fan Outlet Restrictor
Fan Outlet Flange
Flexible Tubes
Fig. 21
5.0 Installation
5.2
Fan Outlet Restrictor
Rear Flue only up to 500mm (19
1. Release the four latches holding the combustion box
door (Fig 18). Remove the combustion box door by
pulling forward (Fig. 17).
2. Release the 5-pin electrical plug connecting the
pressure switch and fan (Fig. 19). Withdraw the fan
assembly by pulling forwards from the top edge (Fig. 17).
3. Take the sheetmetal restrictor (supplied in the kit of
parts), check that the number stamped on the restrictor
matches the appliance (e.g. 50 stamped on the restrictor
is for PFL 50 appliance).
4. Fit the restrictor to the fan outlet flange, bending the 3
lugs equally ensuring the restrictor seals against the fan
outlet flange (Fig. 20).
5. Re-assemble the fan assembly and combustion box
door ensuring that the flexible tubes from the fan unit to
the pressure switch are routed correctly and that they
are not kinked or flattened (Fig. 21).
Pressure
Switch
5
/
in)