3.0 Overheat Cut-Off Device

3.1
Overheat Cut-Off Device
1. Your boiler is fitted with an additional safety device
which shuts down the appliance should the system
overheat. The "overheat" indicator light will be
illuminated if the appliance needs resetting.
NOTE: Any interruption to the electricity supply may
cause the device to operate. In the case of persistant
operation of the device, turn off the boiler and
consult your service engineer as an appliance or
system fault is indicated.
3.2
Resetting
1. To reset the device follow these instructions.
2. Allow the boiler to cool if hot.
3. Remove the lower door panel by following the
sequence of diagrams (Fig. 4).
5. Turn the boiler thermostat control knob fully anti-
clockwise to the OFF position marked '0' (Fig. 5).
6. Wait 10 seconds.
7. Turn the control knob clockwise to the required
thermostat setting, the overheat light will go out and the
boiler will commence sparking and fire up automatically
when the boiler has sufficiently cooled (Fig. 6).
8. No adjustments to the gas controls or boiler
thermostat are required.
*