(26) Remove the Snap Ring (S9).
(27) Remove the Torque Limiter Bushing (2510),
and Torque Limiter Spring (2511).
Note:
When reinstalling the Torque Limiter Assembly,
ensure that the Torque Limiter Spring is placed
into the deeper slot of the Separation Roller.
<Cleaning Torque Limiter Bushing, and Torque
Limiter Spring>
Clean the Torque Limiter Bushing, and Torque
Limiter Spring with a soft cloth, saturated with
Water.
(28) Remove the Separation Roller (2509).
<Cleaning Separation Roller>
Clean the Separation Roller with a soft cloth,
saturated with Water.
(29) Disconnect the Read Point Sensor Harness
(2858), and remove Sensor (131) (Original
Detection Sensor).
(30) Disconnect all Harnesses on the ADF PC
Board.
(31) Remove 2 Screws (19).
(32) Remove the i-ADF PC Board (2847).
(33) Remove 2 Screws (24).
(34) Remove the ADF Motor (2601).