No.
66
Transfer Current Side 2
(Small Width)
(Factory use only)
67
ADF Image Density
68
Paper Loop (Tray 3)
69
Stamp Position Adjust
70
Not Used
71
ADF Read Main Scan Pos.
(Reverse Side)
72
Original Lead Edge ADF
(Reverse Side)
73
Original Trail Edge ADF
(Reverse Side)
74
Stamp Position Adjust
(Reverse Side)
75-76 Not Used
77
Add Toner Level
78
Paper Loop (Tray 4)
79
MTF Adjust
80
Laser Power Control
(Factory use only)
81
Grid voltage Control
(Factory use only)
82
Bias DC Voltage Control
(Factory use only)
83
Temperature Sensor Value
84
Humidity Sensor Value
85
Not Used
86
ADF Reverse Stop Posi.
87
ADF Exhaust Stop Posi.
88-89 Not Used
90
ADF Image Read Start
91
Original Lead Edge ADF
92
Original Trail Edge ADF
93
ADF 100% Image 1-Sided
94
ADF 100% Image 2-Sided
Ver. 1.0
Item
Transfer Current
Compensation of ADF image density.
Individual Fine Adjustment for Tray 3
Adjustment of verification stamp position.
Adjustment of ADF horizontal image read
start position.
Adjustment of ADF Original Lead Edge
Adjustment of ADF Original Trail Edge
Adjustment of Stamp Position
Adjustment of Toner supply
Individual Fine Adjustment for Tray 4
Adjustment of Scanning Sharpness by digital
image processing for Text /Photo Copy Mode.
Value of Gamma Table for Photo Mode.
Value of Laser duty of Check pattern.
Value of Laser duty of Black pattern.
Value of Temperature sensor.
Value of Humidity sensor.
Adjustment of ADF reverse stop position.
Adjustment of ADF exit stop position
Adjustment of ADF horizontal image read
start position.
Adjustment of original detection timing.
Adjustment of trail edge detection timing.
Adjustment of magnification for 1-sided.
Adjustment of magnification for 2-sided.
F6 Mode
Remarks
266
DP-8020E/8020P/8016P
Setting
Range
-20 - +20
0.15uA
-99 - +99
-99 - +99
-50 - +50
0.3mm
-99 - +99
0.05mm
-99 - +99
0.3mm
-127 - +127
0.3mm
-50 - +50
0.3mm
-1 - +1
1
-99 - +99
-2 - +2
1
-99 - +99
(Read Only)
-99 - +99
(Read Only)
-99 - +99
(Read Only)
0 - 255
(Read Only)
0 - 255
(Read Only)
-99 - +99
0.3mm
-99 - +99
0.3mm
-99 - +99
0.05mm
-99 - +99
0.3mm
-127 - 127
0.3mm
-9 - +9
0.1%
-9 - +9
0.1%
SEP 2006