Panasonic DP-8020E Service Manual page 234

Hide thumbs Also See for DP-8020E:
Table of Contents

Advertisement

Code
Mode
503
XMT/
RCV(V.34)
504
RCV/V.34
(Polling)
505
XMT/V.34
(Polling)
540
XMT ECM
541
XMT ECM
542
XMT ECM
543
XMT ECM
544
XMT ECM
550
RCV ECM
554
RCV ECM
555
RCV ECM
570
RCV
571
XMT
580
XMT
581
XMT
582
XMT
601
XMT
623
XMT
630
XMT, or
RCV
(Polling)
631
XMT
Ver. 1.0
Fax Information Codes
Phase
Description of Problem
B, C, D CS of modem is not able to turn
ON during training.
B
Polling is rejected from the remote
station.
B
Polling XMT is rejected.
B
No response after transmitting 3rd
CTC, or DCN received.
D
No response after transmitting 3rd
EOR, or received DCN.
D
No response to the 3rd RR
transmitted, or received DCN.
D
T5 timer (60 sec.) elapsed without
MCF.
D
Stopped Transmission after EOR
Transmission.
C
Timer between frames in phase C
has elapsed.
D
Transmitted ERR after receiving
EOR.
D
Transmitted PIN after receiving
EOR.
B
Password, or machine code did
not match during remote
diagnostic communication.
B
Remote unit did not have the
remote diagnostic function.
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
B
Sub-address SEP (for Polling)
transmission to a unit that has their
DIS bit 47 (NSF bit 130) OFF.
ADF Door was opened during ADF
transmission.
A
No original was in the ADF. (Built-
in dialer engaged)
B
Redial count over.
A
"STOP" key was pressed during
Auto Dialing.
FXB PCB defective.
Line disconnected.
No polling original set.
No polling original set.
Incompatible interface.
Faulty line.
MJR PCB abnormal.
Remote unit abnormal.
Remote unit abnormal.
Faulty line.
MJR PCB abnormal.
Defective remote station.
Faulty line.
Faulty line, and Operator Call requested
by RX side.
Sub-address transmission to a unit that
has no Sub-address function.
Sub-address transmission to a unit that
has no Sub-address function.
Sub-address transmission to a unit that
has no Sub-address function.
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the ADF.
No dial tone detected. Sensor did not
detect dial tone. (Country dependent)
Busy tone is detected. (Country
dependent) T1 timer (35±5 sec) elapsed
without a signal from the receiver.
234
DP-8020E/8020P/8016P
Possible Cause(s)
SEP 2006