1. Destination

Enter the network address for the Router connected to the communication unit. The
IP address is "172.16.0.0", and therefore the Subnetmask setting will be
255.255.0.0/16.

2. Gateway

Set the IP address for the Router side port connected with FB-2000 for the Gateway.
The actual IP address here will be 192.168.1.2, and make the IP address a static IP
address.

3. Metric

The routing information with the smallest metric (router hop number) will be used as
the optimum route. The maximum metric is "15", and if the number of metric surpasses
this number, it will be assumed as inaccessible.
Since there is 1 router here, "1" is the appropriate value to be set.
When you have completed the setting, click Add. When you wish to edit the setting,
click Edit.
7-11
7.1 LAN IP address