5. Board Replacement

When you have replaced the board, confirm that no error message is being issued, and
then execute the communication test.
Exchanged
substrate
Communication
All settings for the Communication unit
unit
Settings -> Basic settings -> Serial port
MODEM board
Note)Replace the EEPROM with the original one.
All settings for the Communication unit excluding those
described above.
Register the contacts in all Settings menu and in Contacts
menu.
Those listed below are mandatory in particular.
1) Settings -> Basic settings -> Analog ports
2) Settings -> PBX settings
HUB board
3) Settings -> Network settings -> IP address ->
4) Settings -> Network settings -> WAN
IF board
No setting required
POWER board
No setting required
Display, Contacts, Sound, and Settings menu
Handset:
FB-8000
Incoming
indicator:
No setting required
FB-3000
Change the dialing method from DP (dial pulse) method to
Analog phone:
PB (push button) method.
FC755D1
Dip SW -> #1 ON
FAX:
Initialize EEPROM and confirm ON/OFF status for ECM and
FAX-2810
the MODEM settings. These settings are to be changed
FAX-2820
according to the communication status.
Antenna unit:
FB-1500
No setting required
FB-1250
DHCP server -> USE
Note) Pay attention to terminals that are to have fixed IPs
allocated; stataic IP addresses can be set in
lease information.
Note) Set the Streaming IP data by following the contract.
Note) Contact: Only the contacts saved in the Handset
Setting for Settings -> SIP is mandatory in particular
Treatment