[Cause]
When VOLUME level of FB-3000 is changed, it is overwritten in the flush memory. It takes one
minute to complete overwrite. When LAN cable is disconnected or the communication unit is
turned off before completion of overwrite, contents of flush memory are corrupted. In this
condition, FB-3000 memory backs to manufacturer's default at next power on. Default of MAC
address of FB-3000 is common to all units and therefore, FELCOM500/250 does not recognize
the FB-3000s in the system properly.
[Remedy]
Update the software to 1650220-01.15 and reprogram the MAC address of FB-3000.
Down load the update software from Technet.
Number of FB3000 installed
One unit only
More than one unit
List of Latest software
Unit
Communication unit
Handset
Incoming Indicator
[Factory modification]
FB-3000: 000106, 000108, 000113, 000117, 000121, 000123, 000125-000129, 000131,
000132, 000135, 000136, 000146, 000148, 000150, 000151, 000153-000155,
000157, 000160, 000161, 000164, 000166, 000168, 000169, 000176, 000181,
000183, 000184, 000186-000189, 000192-000194, 000196, 000200-000203,
000205, 000207, 000208, 000212, 000216, 000219, 000224, 000228, 000235,
000240, 000243, 000247, 000249, 000250, 000253, 000255, 000258, 000262,
000266, 000270, 000290, 000292-000297, 000299, 000300, 000302-000306,
000308-000310, 000312-000315, 000346-000348, 000350-000358,
000360-000363, 000365, 000366, 000368-000375, 000377, 000378,
000380-000387, 000398, 000400, 000402-000407, 000416, 000419-000438
MAC Address
Normal or Default
One unit only default
More than one unit are
default
Program number
1650207-02.02
1650217-02.02
1650220-01.15
Operation
Normal
Normal
Units
having
same
address do no ring.
Reference
FQ5-2010-012
FQ5-2010-011
2/7