No.
Item
32
Telephone handset (option)
34
Overheat protection
35
PC interface applications (Option)
36
Power supply unit and power con-
sumption of the machine
37
Ambient condition
1) Operating condition
2) Storage condition
40838301TH Rev.1
Table 1.5.1 (8/9) Basic Performance Specifications
General telephone function is available while the power is on.
Note: In the fax special versions, general telephone is avail-
The heater of the fuser unit is controlled within the predeter-
mined temperature range by the thermistor. If the tempera-
ture of the heater exceeds the range, the LCD displays
"PRINTER ALARM 4".
Furthermore, the built-in thermostat in the fuser unit prevents
the heater from being overheated even in the event of the
failures in the above temperature control circuit.
The following four modes are supported:
1) PC local printer function
2) PC scanner function
3) PC FaxModem function
4) Location Programing function
Note: This function will be supplied as the OKIFAX 5400
For, details, see product specification for MFP.
Power consumption of the machine
(Typical power)
Transmit
Receive
Local copy
Standby
(Power Save OFF)
Standby
(Power Save ON)
Note: Chart; ITU-T No. 1
See Figure 1.5.1
See Figure 1.5.1
Specifications
able even when the power is off.
option in case Oki Data can get the approval in
respective countries without modifying the optional
unit.
version
160W
210W
16.6W
** US/CANADA version has no power save mode.
1 - 17
US/CANADA
INT'L
version
60W
60W
160W
210W
16.6W
0.5W