7-3.2 Operating with the Operation Panel - 2

Forward /reverse run function: Forward / reverse run (Parameter P003=1)
•EFrequency setting

Example for rotating in forward direction at operating frequency 25Hz

Power ON
Forward
run setting
Run command
Frequency
setting
Changing
the frequency
Stop command
: Potentiometer setting (Parameter P004=0)
The main display lamp will turn ON.
(Operation status display mode)
Press the UP button to set rotation
direction.
(Press the DOWN button to set
reverse run.)
Press the RUN button.
The run state will be entered, but
RUN
as the frequency setting dial is
set to Min., the OV stop state will
be entered.
Gradually turn the frequency setting
dial clockwise, and then motor will
start to run. When "25.0" is displayed,
the motor is operating at 25Hz.
Operating frequency is set to 50Hz.
Turn the frequency setting dial
clockwise to MAX. position, and
rotation speed of the motor will
increase. When "50.0" is displayed
on the main display, the motor
is operating at 50Hz.
Stopping operation
Press the STOP button.
The motor will start to decelerate
STOP
and will stop.
31