P014£ºMax. output voltage
Used to set the max. output voltage.
Data setting range(V)
* When "0" is set, the power voltage value
will be output.
Note
•EA voltage exceeding the power voltage cannot be output.
•EThis setting does not affect the DC brake level.
P015£ºS-shaped acceleration/deceleration mode
The acceleration/deceleration mode can be selected between linear and S-shaped (quadratic
and cubic) mode.
Data setting
value
0
Linear acceleration/deceleration ( Factory setting data)
1
S-shaped acceleration/deceleration ( Quadratic curve)
2
S-shaped acceleration/deceleration ( Cubic curve)
Acceleration time
Note
•E
The acceleration/deceleration time is always the same regardless of the acceleration/
deceleration mode (Linear or S-shaped acceleration/deceleration).
Output
1 to 500
voltage
Details
Deceleration time
Max.
output voltage
Base
Output
frequency
frequency
Related
parameters
Quadratic
curve
Linear
Cubic curve
Acceleration time
Related
parameters
Power
voltage
P005, P008
P001, P002
¡«
P061
P066