7-3.4 Operating With The Operation Panel -4 - Panasonic VF100 Instruction Manual

Table of Contents

Advertisement

7-3.4 Operating with the Operation Panel -4

Forward / reverse run function: Forward run/reverse run (Parameter P003=1)
•EFrequency setting
Example for rotating in forward direction at operating frequency 25Hz
Power ON
Operating
frequency
setting
Forward
run setting
Run command
Operating
frequency
setting
[Continued to next page]
38
: Digital setting (Parameter P004=1)
The main display lamp will turn ON.
(Operation status display mode)
Press the MODE button.
MODE
Press the SET button.
SET
(The main display will flicker.)
Press the UP or DOWN button
Press the UP and DOWN buttons
to display "25.0Hz" on the main
display.
(The main display will flicker.)
Press the SET button to set the
SET
data.
Press the UP button to set the
rotation direction.
(Press the DOWN button to set
reverse run.)
Press the RUN button.
The motor will start rotating in
RUN
the forward direction and operate
at 25Hz.
Forward run operation at operating frequency 50Hz.
Press the MODE button.
MODE
Press the SET button.
SET
(The main display will flicker.)
.
.
.