P150: Password - Panasonic VF100 Instruction Manual

Table of Contents

Advertisement

P150£ºPassword
A password can be set to prevent unintentional changes to the parameter data after
they have been set.
Data setting range
* "0000" indicates that there is no password.
When setting password, press the MODE SW in the "control status monitor mode" and password
indication changes to "PS". After the password is input and the MODE SW is pressed, "custom mode",
"function setting mode" and "built-in memory setting mode" can be called.
No password is displayed in password input indication "PS". Press the MODE SW and enter to
"operation status display mode".
[Procedures for changing parameter data after setting password]
•EWhen password is set to "7777"
Enter the operation status display mode.
STOP
(Press the STOP SW during operation to stop the inverter.)
Press the MODE SW four times and enter password
MODE
input display.
("PS" is displayed and "PS" will flicker.)
Press the UP/DOWN buttons to display the previously
set password. (The main display will flicker.)
Press the SET button to display "custom mode"
SET
(Example: When the previous parameter No. is U001.)
After this step, the data is changed with the normal changing procedures.
•E After the parameter is set, the "custom mode", "function setting mode" and "built-in memory
setting mode" cannot be called without inputting the password.
(Write down the password so that you do not forget it.)
0000 •E1 to 9999
If password is unknown, press the
MODE button to return to "0000".