7-3.3 Operating with the Operation Panel - 3

Forward /reverse run function: Rotation direction setting mode (Parameter P003=0)
•EFrequency setting
Example for rotating in forward direction at operating frequency 25Hz
Power ON
Operating
frequency
setting
Run command
Operating
frequency
setting
[Continued to next page]
34
: Digital setting (Parameter P004=1)
The main display lamp will turn ON.
(Operation status display mode)
Press the MODE button.
MODE
Press the SET button.
SET
(The main display will flicker.)
Press the UP and DOWN buttons
to display "25.0Hz" on the main
display.
(The main display will flicker.)
Press the SET button to set the
SET
data.
Press the RUN button.
The factory setting is forward run,
RUN
so the motor will start rotating in
the forward direction, and will
reach 25.0Hz operation.
Forward run operation at operating frequency 50Hz
Press the MODE button.
MODE
Press the SET button.
SET
(The main display will flicker.)
.
.
.