P151£ºSetting data clear
The set data can be changed to the factory setting data in a batch.
Data setting
value
0
Data value that indicates normal state.
1
Changes all data regardless of vector control to the factory settings.
2
Changes all data to the factory settings.
3
Changes function distribution in the custom mode to the distribution at factory setting.
*
Data related to vector control
"P130: Motor capacity"
"P131: No. of motor poles"
Note
•E Setting value is changed to the value other than "0". Press the SET button and when the
displayed value automatically changes to "0" after data changing, the change is completed.
140
Details
"P133: Voltage compensation constant"
"P134: Slip compensation frequency"
*