9.4.2 Detecting an Error

iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N /
/ iR4570N / iR2230 / / / iR3530 /
Error code
E000
E001
E002
E003
E007
E014

9.5 Parts Replacement Procedure

9.5.1 Fixing Unit

9.5.1.1 Removing the Right Cover (rear)

iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N /
/ iR4570N / iR2230 / / / iR3530 /
1) Open the pedestal right door [1]. (if equipped with a 2-Cassette Pedestal-
Y2)
2) Open the right lower door [2].
3) Remove the 5 screws [3], and detach the right cover (rear) [4].
[2]
[1]

9.5.1.2 Removing the Right Door

iR3570 / iR4570 / / iR3570N / / iR4570N / iR2230 / / / iR3530 /
1) Open the right door.
Detail code Symptom
0000
The fixing temperature fails
to increase.
0000
The thermistor detects
overheating.
0001
A hardware circuit detects
overheating.
0002
The sub thermistor detects
overheating.
0000
The fixing temperature fails
to reach a specific level.
0000
The fixing temperature has
dropped to an abnormally
low level.
0000
The fixing film rotates in an
abnormal way.
0000
The machine detects a
fixing motor error.
[3]
[3]
[3]
[4]
F-9-6
As part of its protective mechanism, the machine checks for the following er-
0006-6013
ror conditions:
Description
In the course of start-up control, the thermistor reading
is less than 30 deg C 1 sec after the start of power supply
or is less than 70 deg C 2 sec after the start of power
supply; the machine will identify an error condition if
any of the foregoing continues for 200 msec or more.
The thermistor detects 235 deg C for 200 msec or more
continuously.
A hardware circuit detects overheating in relation to the
thermistor (main or sub).
The thermistor detects 295 deg C or more for 200 msec
or more continuously.
In the course of start-up control, the thermistor detects a
temperature lower then 115 deg C for 200 msec
continuously after it has detected 100 deg C; the
thermistor detects a temperature less than 150 deg C for
200 msec or more continuously after it has detected 140
deg C; or, the thermistor detects a temperature lower
than 165 deg C for 20 msec or more continuously 1 sec
after it has detected 160 deg C.
In the course of normal temperature control, the
thermistor detects a temperature lower than 140 deg C
for 20 msec or more continuously.
The reading of the main thermistor is in excess of 100
deg C with the fixing motor in a locked state and, in
addition, the machine fails to detect the marker signal
for 6 sec.
During operation, the machine detects an overload
condition continuously for 3 sec or more.
0007-7874
2) Remove the screw [1], and detach the fixing plate [2].
3) Remove the joint shaft [1], and free the extension delivery unit [2] from
the right door.
0007-7879
Chapter 9
T-9-3
F-9-7
F-9-8
9-5