Installation In A Netspot Accountant (Nsa) Environment; Installing The Ne Controller; Installing The Ne Controller-A1 - Canon iR3570 Service Manual

Canon ir4570; ir3570; ir2870; ir2270 laser multifunction printer/copier
Hide thumbs Also See for iR3570:
Table of Contents

Advertisement

11) Connect the power cable to the wall outlet, and turn on the main power switch. See that the machine is in a standby state, and start service mode.
12) Make the following selections in the machine's service mode (COPIER>FUNCTION>INSTALL>CARD); then, enter the appropriate card number (1 to 2001).
-Use the number that is the lowest of all the numbers that the user will be using.
-As many as 1000 cards may be used starting with the number entered.
13) Turn off the control panel power switch.
14) Turn off and then on the main power switch.

2.6.4 Installation in a NetSpot Accountant (NSA) Environment

iR2270 / iR2870 / / iR2270N / / iR2870N / iR2230 / / iR3530 /
1) Make the following selections in user mode: system control setup>group ID control>count control; then, see that the following numbers are available:
ID00000001 to ID00001000. (If you entered '1' in service mode: COPIER>FUNCTION>INSTALL>CARD.)
2) Make the following selections in user mode: system setup>network setup>TCP/IP setup>IP address. Set the following: 'IP address', 'gateway address', 'subnet
mask'.
Unless you have set 'system control group ID' and 'system control ID No.', you will not be able to execute 'register card to device' as part of NSA setup work.
3) In user mode, enter numbers of your choice for 'system control ID' and 'system control ID No.' as part of system administrator information.
4) Turn off the control panel power switch.
5) Turn off and then on the main power switch.

2.7 Installing the NE Controller

2.7.1 Installing the NE Controller-A1

iR2270 / iR2870 / iR3570 / iR4570 / / / / / iR2230 / / iR3530 /
When installing the NE Controller-A1 to its host machine, take note of the following:
1. be sure to perform the work in compliance with the laws and regulations of the country in question.
2. be sure that the host machine has properly been installed before starting the work.
3. be sure to disconnect the power plug of the host machine before starting the work.
4. be sure to identify the screws by type (length, diameter) and location.
5. be sure the settings data are ready on the PC at the service station.
1) Remove the 2 screws [2] of the top cover [1], and detach the cover.
2) Connect the connector [1] of the power supply unit to the connector [2] as shown.
F-2-87
[1]
[2]
[2]
F-2-88
Chapter 2
0007-2764
0007-5625
2-21

Hide quick links: