SERVICE SCHEDULE
1.3

Periodic check items (main body)

A. Periodic check (I) (Every 200,000 copies/prints)
No. Classification
1
Charging
(1) Changing grid plate
corona
65AA2507*
(2) Changing grid spring
65AA2509*
2
Transfer
(1) 1st transfer roller /K
belt
65AA2604*
25 mode count reset
(2) 1st transfer roller /C
65AA2612*
25 mode count reset
(3) 2nd transfer roller /U
65AA2611*
(4) Belt drive roller cleaning
(5) Transfer belt
65AA2642*
(6) Toner collection sheet /1
65AA-293*
3
2nd transfer (1) 2nd transfer roller /L
65AA4501*
4
Fixing
(1) Fixing cleaning unit
65AA-573*
25 mode count reset
(2) Paper exit roller /Up
(New type only)
65LA5343*
5
Paper exit
(1) Paper exit roller
(New type only)
65LA4808*
(2) Paper exit guide roller /2
65AA4818*
(3) Paper presser roller
65AA4849*
*1
Reset "5. Parts counter" and "1. Count of special parts" to prevent a image disturbances in the 25 mode
when replacing the 1st transfer roller /Y/M/C/K.
*2
Reset "5. Parts counter" and "1. Count of special parts" in the 25 mod when replacing the fixing clean-
ing unit. Otherwise, the message "You need to replace the fixing cleaning unit. Please call the service."
appears and the copy/print prohibition state is started.
2
KONICA MINOLTA 8050/CF5001/C500/8150 Field Service Ver.3.0 Dec. 2004
Service item
Quantity
4
8
1
3
1
1
1
1
1
2
1
4
2
Implementation classification
Cleaning Check Lubrication Replacement
3-8
Materials•
Tools used
*1
1
Hydro wipe/
drum cleaner
*2
*3
*4