ERROR CODE LIST
Classification Abnormality
code
Image
E46-16
process-
ing
abnor-
mality
E46-17
E46-19
E46-21
E46-23
E46-24
KONICA MINOLTA 8050/CF5001/C500/8150 Field Service Ver.3.0 Dec. 2004
Causes
When scanning the image,
access to compression device
or some other improper pro-
cess took place even though
there was no resource.
When processing the image,
filter coefficient cannot be prop-
erly prepared.
When accessing the memory
device, software fault was
detected.
Expansion process from mem-
ory to page memory is not
completed within the specified
time.
Compression process from
page memory to memory is not
completed within the specified
time.
Evolution from memory to page
memory is not completed
within the specified time.
Compressed data transfer from
memory to memory is not com-
pleted within the specified time.
When scanning the image,
SVV is not turned OFF within
the specified time and there-
fore scanning of next page
cannot be started.
Shading correction abnormality
(GA abnormality)
5-18
Resulting
Estimated abnormal parts
operation
Main body
Image processing board (IPB)
stops immedi-
Program of overall control
ately and main
board (OACB)
relay (RL1) is
turned OFF.
Printer control board (PRCB)
Image processing board (IPB)
Program of overall control
board (OACB)
Printer control board (PRCB)
Image processing board (IPB)
Overall control board (OACB)
Image processing board (IPB)
Program of image processing
board (IPB)