At The Platform Controls; Test The Horn; Test The Tilt Sensor Alarm; Test The Operating Envelope - Genie Z-135/70 Operator's Manual

Hide thumbs Also See for Z-135/70:
Table of Contents

Advertisement

Operator's Manual
Inspections

Test the Operating Envelope

28 Push one of the LCD screen
control buttons shown until
PRI BOOM ANGLE TO
GRAVITY is displayed.
29 Raise the primary boom and observe the LCD
screen.
Result: The primary boom should raise and the
LCD screen should display the primary boom
angle in degrees.
30 Lower the primary boom.
31 Simultaneously push the 2
LCD screen control buttons
shown to activate status
mode.
32 Push one of the LCD screen
control buttons shown until
SEC BOOM ANGLE is
displayed.
33 Push and hold the secondary boom up/extend
button.
Result: The secondary boom should raise and
the LCD screen should display the secondary
boom angle in degrees.
The secondary boom should raise and then
extend. The secondary boom should not extend
until it is fully raised.
34 Push and hold the secondary boom down/retract
button.
Result: The secondary boom should fully retract
and then lower. The secondary boom should not
lower unless it is fully retracted.
34

At the Platform Controls

Test Emergency Stop
35 Turn the key switch to platform control.
36 Push in the platform red Emergency Stop button
to the off position.
Result: The engine should turn off and no
functions should operate.
37 Pull out the red Emergency Stop button and
restart the engine.

Test the Horn

38 Push the horn button.
Result: The horn should sound.

Test the Tilt Sensor Alarm

39 Push a button or move a switch, such as the
engine idle control.
Result: The alarm should sound at the platform
controls.
Z-135/70