model naming
[ COPY / CLEAr ] MOdEL COPY / MOdEL CLEAr
The Copy/Clear function enables you to copy data from the currently selected model to another model, or to copy another model's
data into the currently selected model. Data can be cleared on the model that is currently selected.
Copy Model Data - Current Model to Another Model
1) Press the Function key to move the cursor to [COPY/
CLEAR] in the MODEL Programming Window.
2) To copy data from the currently selected model
(<MASTER>) to another model (<SLAVE>), press the
INC/+ or DEC/- keys to scroll the model numbers up or
down to the model number you would like to copy the
current model to (e.g. scroll M02: to the right of the cursor).
3) After you have selected the model number you wish to
copy the currently selected model to, press the ENTER
key. The Programming Window will display MODEL
COPY! YES=<INC> and NO=<DEC>.
4) Press the INC/+ key to copy the data from the currently
selected model to the new model. All of the data,
including the name, will be copied.
Copy Model Data - Another Model to Current Model
1) Press the Function key to move the cursor to [COPY/
CLEAR] in the MODEL Programming Window.
2) To copy data from another model (<SLAVE>) to the
currently selected model (<MASTER>), press the
to change the currently selected model to <Slave>.
The cursor will point to the left and <MASTER> will be
displayed above the model you would like to copy from.
3) Press the INC/+ or DEC/- keys to scroll the model numbers up or down to the model number you would like to copy from, then
press the ENTER key. The Programming Window will display MODEL COPY! YES=<INC> and NO=<DEC>.
4) Press the INC/+ key to copy the data from the other model to the currently selected model. All of the programming data from
the other model, including the name, will be copied to the currently selected model.
Clearing Model Data
1) Press the Function key to move the cursor to [COPY/
CLEAR] in the MODEL Programming Window.
2) Press the
key to change the currently selected model
(<MASTER>) to <SLAVE>.
3) Press both the INC/+ and DEC/- keys at the same
time to select (---:CLEAR), then press the ENTER key.
The Programming Window will display MODEL COPY!
YES=<INC> and NO=<DEC>.
4) Press the INC/+ key to clear all data from the currently
selected model.
The cursor in these screens are stationary and the model labels scroll up and down. The model that you're currently working
with is displayed directly across from the cursor. The cursor always points toward the <SLAVE> model.
key