SCANNER UNIT

4.6 SCANNER H. P. SENSOR/PLATEN COVER SENSOR

[B]
1. Remove the exposure glass and upper rear cover. (See Exposure
Glass/Operation Panel/Upper Cover.)
2. Remove and replace the platen cover sensor [A] (1 connector).
3. Remove the scale bracket [B] (1 screw) remove and replace the scanner
H.P. sensor [C].
(A193)
[C]
5-14
[A]
A193R015.wmf