IMAGE DENSITY ADJUSTMENT BY KEY OPERATOR

12. IMAGE DENSITY ADJUSTMENT BY KEY
OPERATOR
Usually, the image density is adjusted with SP2-911 (this changes the
coefficient for the TD sensor output). However, if the user wishes to change
the image density, the service representative can instruct the user to do this
using the following procedure.
SP2-911
SP2-911
1. Press the User Tool key.
2. Select the System menu.
3. Press the Darker (or Lighter) key and the # key at the same time.
NOTE: At this time, the current setting level is displayed on the image
density LED. See illustration 1.
4. When holding down both the Darker (or Lighter) key and the # key for
over 3 seconds, the image density LED will be changed to a darker level
(or lighter level). See illustration 2.
NOTE: 1) If the image density level is changes to a darker setting, the
machine automatically supplies toner.
2) Do not select the "0" level.
(A193)
Value
4
3
Lighter
Illustration 1
Value
4
3
Lighter
Illustration 2
5-44
2
1
0
Darker
2
1
0
Darker
A193R518.wmf