4.6 PAPER END AND UPPER LIMIT SENSOR REPLACEMENT
1. Remove the paper tray.
2. Remove the paper end and upper limit sensor with bracket [A] (1 screw, 2
connectors).
3. Replace the paper end sensor [B] or replace the upper limit sensor [C].
NOTE: When reinstalling the sensor ass'y, insert the harness into the clamp
to prevent the harness from touching the paper.
SM
REPLACEMENT AND ADJUSTMENT
[C]
[A]
[B]
8-13
G697O012.wmf
(G697)