Original Set Sensor And Width Sensor Replacement; Replacement - Ricoh A193 Service Manual

Hide thumbs Also See for A193:
Table of Contents

Advertisement

REPLACEMENT AND ADJUSTMENT
4.5 ORIGINAL SET SENSOR AND WIDTH SENSOR

REPLACEMENT

[D]
[E]
1. Open the DF feed cover.
2. Remove the entrance guide [A] (3 screws).
3. Replace the following sensors.
Original Set Sensor [B]
Original Width Sensor 1 [C]
Original Width Sensor 2 [D]
Original Width Sensor 3 [E]
(A628)
[A]
[B]
[C]
7-18
A628O020.wmf