1.4 EXPOSURE GLASS/OPERATION PANEL/UPPER COVER

[G]
[D]
[F]
1. Remove the left scale [A] and rear scale [B] (5 screws).
2. Remove the exposure glass [C].
3. Remove the operation panel [D] (5 screws).
NOTE: When reinstalling the operation panel, connect the grounding
terminal [E] so that the wire is vertical.
4. Remove the operation lower cover [E] (4 screws).
5. Remove the scanner right cover [F] (1 screw).
6. Remove the scanner left cover [G] (1 screw).
7. Remove the scanner rear cover [H].
SM
[B]
[A]
5-3
EXTERIOR
[H]
[C]
[F]
A193R003.wmf
(A193)