8. Trouble code
(4)
Stapler/Crease Clock Sensor (Saddle Section)
Staple/Folding Motor Clock Sensor (PI14-FN)
Staple/Folding Motor (M7-FN)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of motor for proper
2
drive coupling, and correct as neces-
sary.
3
PI14-FN I/O, sensor check
M7-FN operation check when the Main
4
Power Switch is turned OFF and ON.
5
PWB-A FN replacement
8.3.9
C11C1: Punch Control Board malfunctions
Finisher Control Board (PWB-A FN)
Punch Control Board (PWB-B PK)
Step
Turn OFF the Main Power Switch, wait
1
for 10 sec. or more, and turn ON the
Main Power Switch.
Check the connection condition
2
between the Punch Unit and PWB-A
FN.
Measure the voltage between CN14-5
3
(+) and CN14-3 (-) of the PWB-A FN. Is
the voltage 24VDC?
4
Initialize Punch Unit EEP-ROM.
5
PWB-B PK replacement
6
PWB-A FN replacement
64
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.0 Jul. 2005
Finisher Control Board (PWB-A FN)
WIRING DIAGRAM
Control signal
—
—
PWB-A FN CN9A FN-5 (ON)
PWB-A FN CN6A FN-1 to 2
—
WIRING DIAGRAM
Control signal
—
—
—
—
—
—
Location
(Electrical
components)
—
—
FS-603 G-8
FS-603 B-3
—
Location
(Electrical
components)
—
—
—
—
—
—