Focus Positioning Of The Scanner And Mirrors Unit - Konica Minolta bizhub C250 Service Manual

Hide thumbs Also See for bizhub C250:
Table of Contents

Advertisement

Field Service Ver. 1.0 Jul. 2005
14.1.2

Focus Positioning of the Scanner and Mirrors Unit

This adjustment must be made in the following case:
• The Scanner Drive Cables have been rewound
[1]
[4]
[3]
[2]
4038F2C181DA
[3]
[4]
4038F3C001DB
[5]
4038F3C002DB
14. Mechanical adjustment
1. Remove two Screws [1] and Lens
cover [2].
2. Slide the Mirrors Unit [3] to the cen-
ter until it is pressed up against the
cutouts in the rails [4].
3. If the Mirrors Unit is not pressed up
against the cutouts, loosen the
adjusting screw (to which red paint is
applied) [5] of the Mirrors Unit and
press the carriage up against the
cutouts. Then, tighten the adjusting
screw.
4. Slide the Mirrors Unit to the left and
install the Lens Cover.
5. Then conduct Scanner positioning
adjustment.