8. Trouble code
8.3.3

C1183: Elevate Mechanism malfunctions

(1) Upper Limit Sensor
Shift Upper Limit Sensor (PI15-FN)
Step
Check the sensor connectors for proper
1
connection, and correct as necessary.
2
PI15-FN I/O, sensor check
3
PWB-A FN replacement
8.3.4

C1192: Front Aligning Plate Motor malfunctions

Front Aligning Plate Home Position Sensor
(PI4-FN)
Front Aligning Motor (M4-FN)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of motor for proper
2
drive coupling, and correct as neces-
sary.
3
PI4-FN I/O, sensor check
M4-FN operation check when the Main
4
Power Switch is turned OFF and ON.
5
PWB-A FN replacement
60
Relevant electrical parts
Action
PWB-A FN CN15A FN-12 (ON)
Relevant electrical parts
Action
Field Service Ver. 1.0 Jul. 2005
Finisher Control Board (PWB-A FN)
WIRING DIAGRAM
Control signal
Finisher Control Board (PWB-A FN)
WIRING DIAGRAM
Control signal
PWB-A FN CN4A FN-2 (ON)
PWB-A FN CN3A FN-2 to 5
Location
(Electrical
components)
FS-603 G-5
Location
(Electrical
components)
FS-603 G-6
FS-603 B-4