3.5.12

Replacing the Deodorant Filter

[1]
3.5.13

Replacing the Dust Filter/Vertical Conveyance

3.5.14

Replacing the Dust Filter/Cooling Fan

[1]
1. Holding onto the hook, take out the
Deodorant Filter [1].
NOTE
• The Deodorant Filter is supplied
with the Toner Cartridge (Black).
Replace it when replacing the Toner
Cartridge (Black).
4038F2C545DA
1. If the optional Automatic Duplex Unit
AD-503 is mounted, remove it.
☞ See AD-503 Service Manual.
2. Remove the Dust Filter/Vertical Con-
[1]
veyance [1].
NOTE
• The Dust Filter/Vertical Conveyance
is supplied with the Transfer Belt
Unit.
Replace it when replacing the
Transfer Belt Unit.
4038F2C020DB
1. If the Dust Filter/Cooling Fan is con-
taminated by dust or foreign matter,
clean it up.
2. Remove the Dust Filter/Cooling Fan
[1].
NOTE
• The Dust Filter/Cooling Fan is sup-
plied with the Waste Toner Box.
Replace it when replacing the
Waste Toner Box.
4038F2C544DA