16. Malfunction code
16.5.71
C6704: Image Input Time Out
MFP Control Board (PWB-MFP)
Step
Select [Service Mode] → [State Confirma-
tion] → [Memory/HDD Adj.] → [Memory
1
Bus Check] → [Scanner→Memory].
Check the connectors between PWB-C
2
and PWB-MFP for proper connection and
correct as necessary.
3
Change PWB-MFP
4
Change PWB-C
16.5.72
C6751: CCD clamp/gain adjustment failure
Scanner Assy
Step
Correct the harness connection between
1
PWB-A and PWB-C if faulty.
Check for possible extraneous light and
2
correct as necessary.
Clean the lens, mirrors, CCD surface, and
3
shading sheet if dirty
Correct reflective mirror of the Scanner if
4
faulty, or change Scanner.
5
Change PWB-A
6
Change PWB-C
372
Relevant Electrical Parts
Action
Relevant Electrical Parts
Action
Field Service Ver. 1.0 Jul. 2005
Image Processing Board (PWB-C)
WIRING DIAGRAM
Control Signal
CCD Sensor Board (PWB-A)
Image Processing Board (PWB-C)
WIRING DIAGRAM
Control Signal
Location (Electri-
cal Component)
Location (Electri-
cal Component)